CME1356R and CME1656R
Additional Maintenance
To Properly Place the Evaporator Covers
Removal:
1.Remove right front panel.
2.Push up on evaporator cover and swing out the base.
3.Use the finger holes to pull the lower inside cover down and swing it out from the machine.
4.Pull upper inside cover out from behind the pump hose.
Note: ALL COVERS MUST BE PROPERLY IN PLACE or the MACHINE WILL MALFUNCTION.
Replacement:
1
Insert Bottom Tabs in 5th.
Slot of Cube Deflectors
Return upper inside cover to its original position.
2.Using finger holes to control the part, insert the two tabs on the bottom of the lower inside cover into the 5th slot of each cube deflector.
3.Push down and insert upper edge of the lower inside cover into the slot on the bottom of the evaporator bracket.
4.Insert evaporator cover into plastic slot at the top of the compartment and then place the lower end onto the reservoir wall.
To drain reservoir (if desired):
1.Remove front panel.
2.Push and hold the Off button.
3.Push and Hold the Clean Button for 3 Seconds to Activate Purge Valve.
4.Push and release Freeze button.
5.Return the front panel to its original position. To Sanitize the Ice Storage Bin
1.Remove all ice.
2.Remove baffle.
3.Switch ice machine OFF or wait for it to be in a cleaning cycle.
4.Mix a 1 gallon solution of warm
5.Wash or spray the entire interior of the ice storage bin with the sanitizer solution. This includes the bottom of the ice machine and the inside of the door, the door gaskets (if any) and door frame.
6.Pour excess sanitizer into the bin to flush the drain system.
7.If the approved sanitizer requires a rinse, rinse all interior surfaces with potable water.
May 2001