Scotsman Ice CME1656R, CME1356R Additional Maintenance, To Properly Place the Evaporator Covers

Page 27

CME1356R and CME1656R

Additional Maintenance

To Properly Place the Evaporator Covers

Removal:

1.Remove right front panel.

2.Push up on evaporator cover and swing out the base.

3.Use the finger holes to pull the lower inside cover down and swing it out from the machine.

4.Pull upper inside cover out from behind the pump hose.

Note: ALL COVERS MUST BE PROPERLY IN PLACE or the MACHINE WILL MALFUNCTION.

Replacement:

1

Insert Bottom Tabs in 5th.

Slot of Cube Deflectors

Return upper inside cover to its original position.

2.Using finger holes to control the part, insert the two tabs on the bottom of the lower inside cover into the 5th slot of each cube deflector.

3.Push down and insert upper edge of the lower inside cover into the slot on the bottom of the evaporator bracket.

4.Insert evaporator cover into plastic slot at the top of the compartment and then place the lower end onto the reservoir wall.

To drain reservoir (if desired):

1.Remove front panel.

2.Push and hold the Off button.

3.Push and Hold the Clean Button for 3 Seconds to Activate Purge Valve.

4.Push and release Freeze button.

5.Return the front panel to its original position. To Sanitize the Ice Storage Bin

1.Remove all ice.

2.Remove baffle.

3.Switch ice machine OFF or wait for it to be in a cleaning cycle.

4.Mix a 1 gallon solution of warm (95-115oF.) water and sanitizer. Follow local codes for sanitizer.

5.Wash or spray the entire interior of the ice storage bin with the sanitizer solution. This includes the bottom of the ice machine and the inside of the door, the door gaskets (if any) and door frame.

6.Pour excess sanitizer into the bin to flush the drain system.

7.If the approved sanitizer requires a rinse, rinse all interior surfaces with potable water.

May 2001

Page 27

Image 27
Contents CME1356R and CME1656R CME1356R and CME1656R Condenser and Ice Machine Layouts CME1356R and CME1656RSerial Number Plate Pre-InstallationLocation & Assembly Bin Control Installation Mount Bulb Bin ControlStacking Kit KSCME6-LG-B Stacking For The Installer Remote Condenser CME1356R and CME1656R Tighten Swivel Nut Coupling InstructionsHead Pressure Control Add-On Kit Electrical Water Filters Follow all applicable codes PlumbingSupply DrainFinal Check List After Utility ConnectionsComponent Location and Function AutoIQ Controller Harvest Cycle Initial Start UpInitial Start 30 seconds Freeze CycleAdjustments If there was a problem during Initial Start UpHow to Adjust the Amount of Water Purge How To Operate The AutoIQ Controller Refrigeration System How The Electronic Cuber WorksWater System VoltHigh Voltage AutoIQ Controller Operation, Beginning freeze Technicians Only Freeze Cycle SequenceLight Technicians Only Harvest Cycle Sequence & Other NotesHarvest Water Light RefrigerationSanitation and Cleaning Additional Maintenance To Properly Place the Evaporator CoversTo drain reservoir if desired Additional Maintenance Water Distributors Additional Maintenance Inlet Water Valve Screen To Clean the Remote Air Cooled Condenser Additional Maintenance Ice Sensors, CondenserProblem or Symptom Possible Cause Probable Correction Service Diagnosis Diagnostic Light AnalysisService Diagnosis Service Diagnosis Components TXV March Operational Characteristics CME1356R Operational Characteristics CME1656R Removal and Replacement Water Level Sensor/Float Stem Removal and Replacement AutoIQ Controller Removal and Replacement Water Level Sensor Removal and Replacement Refrigerant Liquid Charging Check the following Before Calling for ServiceService Bulletin