CME1356R and CME1656R
Removal and Replacement
Inlet Water Valve
1.Remove the left front panel.
2.Shut off the water supply.
3.Push and release the OFF button.
4.Pull the wire harness off the inlet water valve.
5.Remove screws holding the inlet water valve to the cabinet.
6.Pull the valve away from the cabinet and disconnect the outlet tube.
7.Unscrew the water valve from the water inlet tubing. Hold the barbed inlet fitting and rotate the valve.
8.Reverse to reassemble.
9.Push and release the Freeze button.
10.Replace the front panel.
Water Pump
1.Disconnect the electrical power.
2.Remove the front panel.
3.Unplug water pump from its electrical connection.
4.Remove 1 plastic bolt and the reservoir cover.
5.Lift water pump up and disconnect outlet tube.
6.Pull float ball from float stem (it is a snap fit). Pull stem out.
7.Locate water level sensor mounting tabs, compress together to release sensor from bracket.
8.Remove water pump brackets from pump.
9.Reverse to replace.
10.Replace front panel.