Scotsman Ice CME1356R, CME1656R specifications After Utility Connections, Final Check List

Page 16

CME1356R and CME1656R

After Utility Connections

1.Wash out the bin. If desired, the interior of the bin could be sanitized.

2.Locate the ice scoop (if supplied) and have it available for use when needed.

3.Switch on the electrical power. Do not start the machine for 4 hours.

4.Go thru the final check list (below).

Final Check List:

___ 1. Is the unit located indoors in a controlled environment?

___ 2. Has the correct remote condenser been

properly located and mounted?

___ 3. Has the correct electrical power (voltage and phase) been supplied to the machine?

___ 4. Have all the water supply connections been properly made with the correct size tubing?

___ 5. Have all the drain connections been properly made?

___ 6. Has the unit been leveled? Level the unit at the bin.

___ 7. Have all unpacking materials been removed?

___ 8. Is the water pressure adequate?

___ 9. Is the machine secured to the ice storage bin?

___ 10. Is the bin control system been properly installed?

___ 11. Have the drain connections been checked for leaks?

___ 12. Has the bin interior been wiped clean or sanitized?

___ 13. Have any water filter cartridges been replaced?

___ 14. Check all refrigerant lines and conduit lines, for vibration or rubbing and possible failure. Adjust as needed.

___ 15. After 4 hours of electrical power, proceed to Initial Start Up.

May 2001

Page 16

Image 16
Contents CME1356R and CME1656R CME1356R and CME1656R CME1356R and CME1656R Condenser and Ice Machine LayoutsPre-Installation Serial Number PlateLocation & Assembly Bin Control Installation Bin Control Mount BulbStacking Kit KSCME6-LG-B Stacking For The Installer Remote Condenser CME1356R and CME1656R Coupling Instructions Tighten Swivel NutHead Pressure Control Add-On Kit Electrical Plumbing SupplyDrain Water Filters Follow all applicable codesAfter Utility Connections Final Check ListComponent Location and Function AutoIQ Controller Initial Start Up Initial Start 30 secondsFreeze Cycle Harvest CycleIf there was a problem during Initial Start Up AdjustmentsHow to Adjust the Amount of Water Purge How To Operate The AutoIQ Controller How The Electronic Cuber Works Refrigeration SystemVolt Water SystemHigh Voltage Technicians Only Freeze Cycle Sequence AutoIQ Controller Operation, Beginning freezeTechnicians Only Harvest Cycle Sequence & Other Notes HarvestWater Light Refrigeration LightSanitation and Cleaning To Properly Place the Evaporator Covers Additional MaintenanceTo drain reservoir if desired Additional Maintenance Water Distributors Additional Maintenance Inlet Water Valve Screen Additional Maintenance Ice Sensors, Condenser To Clean the Remote Air Cooled CondenserService Diagnosis Diagnostic Light Analysis Problem or Symptom Possible Cause Probable CorrectionService Diagnosis Service Diagnosis Components TXV March Operational Characteristics CME1356R Operational Characteristics CME1656R Removal and Replacement Water Level Sensor/Float Stem Removal and Replacement AutoIQ Controller Removal and Replacement Water Level Sensor Removal and Replacement Refrigerant Liquid Charging Before Calling for Service Check the followingService Bulletin