Cornelius 000 PLUS, 10 Syrup Flavor Change, Cleaning CO2 System GAS Check Valves

Page 31

3. Connect full tank of syrup into syrup system.

SYRUP FLAVOR CHANGE

1.Perform sanitizing procedure on syrup system syrup flavor change will be made on.

2.Check soft drink tank quick disconnects for sticky or restricted operation. Wash disconnects in warm water.

3.Connect full tank of new flavor syrup into syrup system.

CLEANING CO2 SYSTEM GAS CHECK VALVES

SECONDARY CO2 REGULATORS AND CO2 MANIFOLD CO2 GAS CHECK VALVES

(see Figures 2 and 7)

The secondary CO2 regulators and CO2 manifold CO2 gas check valves must be inspected and serviced at least once a year under normal conditions and after any servicing or disruption of the CO2 system. ALWAYS REPLACE BALL SEAT (QUAD RING SEAL) EACH TIME GAS CHECK VALVES ARE SERVICED.

COOLING UNIT CO2 INLET LINE CO2 GAS CHECK VALVE

(see Figures 2 and 7)

CO2 inlet line CO2 gas check valve, located inside Cooling Unit, must be inspected and serviced at least once a year under normal conditions and after any servicing or disruption of the CO2 system. ALWAYS INSTALL NEW BALL SEAT (QUAD RING) SEAL EACH TIME GAS CHECK VALVE IS SERVICED.

27

300614000

Image 31 Contents
This Document Contains Important Information AURORAR10,000 Plus Cooling UnitTable of Contents Table of Contents cont’d Water Pump Motor Operates but Water Pump does not Pump Cooling Unit CO2 Inlet Line CO2 GAS Check ValveWATER-TO-SYRUP ‘RATIO’OF Dispensed Drink TOO LOW or TOO Dispensed Product Produces Foam AS IT Leaves DispensingCooling Unit Description General DescriptionCooling Unit Data System Theory of Operation Flow Diagram Typical Installation Cooling Unit Unpacking and InspectionIdentification of LOOSE-SHIPPED Parts Selecting LocationPlacing Cooling Unit in Location Installing Remote Condenser Coil and FAN ASS’YInstalling Cooling Unit Remote Condenser Coil and FAN ASS’YConnecting Electrical Power Circuit to Cooling Unit Cooling Unit factory warranty Connecting Plain Water Inlet Supply Line to Cooling UnitConnecting CO2 Inlet Supply Line to Cooling Unit Preparing Cooling Unit for Operation Placing Cooling Unit in Operating PositionOperation Service internal components or electrical wiringAdjusting WATER-TO-SYRUP ‘‘RATIO’’ of Dispensed Product Dispensing Station AdjustmentsInstalling Line Identification Label Adjusting Water Flow RateOperating Controls Cooling Unit Refrigeration Power SwitchCooling Unit Carbonator Motor Switch Cooling Unit Circulating Motor SwitchReplenishing CO2 Supply AdjustmentsCleaning and Sanitizing Daily PRE-OPERATION CheckCooling Unit AIR Intake and Exhaust Filters Cooling Unit MaintenanceCooling Unit Carbonator Maintenance Sanitizing Syrup SystemsCleaning CO2 GAS Check Valves Remote Condenser Coil and FAN ASS’Y MaintenancePeriodic Inspection Periodic CleaningCleaning Cooling Unit AIR Intake and Exhaust Filters Preparing Cooling Unit for SHIPPING, STORING, or RelocatingChanging ICE Water Bath Remote Condenser Coil and FAN Assembly MaintenanceSee Figures 2 Parts Identification Primary CO2 Regulator LubricationSecondary CO2 Regulators Water Flow Rate Daily Cleaning of UnitWATER-TO-SYRUP ‘‘RATIO’’OF Dispensed Product Wash Syrup Systems Sanitizing POST-MIX Syrup SystemsSanitize Syrup Systems Flush Syrup SystemsWater Flush Syrup Systems Purge Water OUT of Syrup Systems Restore Operation CO2 GAS Check Valve Replenishing Syrup SupplySyrup Flavor Change Cleaning CO2 System GAS Check ValvesCooling Unit CO2 Inlet Line CO2 GAS Check Valve 300614000 Wiring Diagram LOW or TOO High AdjustmentWATER-TO-SYRUP ‘RATIO’ Dispensed Drink TOOOnly Carbonated Water a Dispensed ProductCarbonation TOO LOW Comes OUT Dispensing Valve Clear But Foams in CUPWarm Product Being Only Carbonated WaterOnly Syrup Dispensed Carbonator MotorOperates but Water Operate Refrigeration PowerTemperature Sensing Water Pump MotorContinuously but does Compressor OperatesNot Form Sufficient ICE Bank Not Operating Wiring DiagramNot Form Sufficient ICE Condenser FAN MotorWarranty This page Left Blank Intentionally One Cornelius Place Anoka, Minnesota 612 800
Related manuals
Manual 52 pages 8.37 Kb