Cornelius 000 PLUS, 10 installation manual Connecting CO2 Inlet Supply Line to Cooling Unit

Page 13

2.Connect flexible plain water inlet supply line (1/2-inch I.D. min.), meeting water inlet supply line requirements of preceding CAUTION note, to Cooling Unit 3/8-in. flare (5/8-18) bulkhead fitting on back of Unit labeled ‘WATER INLET’. DO NOT OPEN WATER INLET SUPPLY LINE SHUTOFF VALVE AT THIS TIME.

CONNECTING CO2 INLET SUPPLY LINE TO COOLING UNIT

(see Figure 2)

WARNING: CO2 displaces oxygen. Strict attention must be observed in the prevention of CO2 (carbon dioxide) gas leaks in the entire CO2 and soft drink system. If a CO2 gas leak is suspected, particularly in a small area, immediately ventilate the contaminated area before

attempting to repair the leak. Personnel exposed to high concentration of CO2 gas will experience tremors which are followed rapidly by loss of consciousness and suffocation.

Connect flexible CO2 inlet supply line to Cooling Unit 1/4-in. flare (7/16-20) bulkhead fitting of back of Unit labeled “CO2 INLET’. DO NOT TURN ON CO2 SUPPLY TO COOLING UNIT AT THIS TIME.

CONNECTING SYRUP SOURCE LINES TO COOLING UNIT SYRUP INLET LINES

(see Figure 2)

Connect syrup source lines, from No. 1 through No. 10 soft drink tanks location, to Cooling Unit syrup inlet lines labeled No. 1 through No. 10. DO NOT CONNECT SOFT DRINK TANKS INTO SYRUP SYSTEMS AT THIS TIME.

CONNECTING COOLING UNIT SYRUP OUTLET LINES TO INSULATED PYTHON SYRUP LINES

(see Figure 2)

Connect Cooling Unit syrup outlet lines labeled No. 1 through No. 10, to insulated python lines labeled No. 1 though No. 10 using BARBED CONNECTORS (item 2). Secure connections with TUBING CLAMPS (item 1).

CONNECTING COOLING UNIT PLAIN WATER OUTLET LINES TO INSULATED PYTHON PLAIN WATER LINES

(see Figure 2)

Connect Cooling Unit plain water outlet lines to insulated python plain water lines using BARBED CONNECTORS (item 2). Secure connections with TUBING CLAMPS (item 1).

CONNECTING COOLING UNIT CARBONATED WATER OUTLET LINES TO INSULATED PYTHON CARBONATED WATER LINES

(see Figure 2)

NOTE: The Cooling Unit carbonated water outlet lines are used to make up the carbonated water circulating system between the Cooling Unit and the dispensing station as explained in SYSTEM THEORY OF OPERATION in GENERAL INFORMATION SECTION.

Connect Cooling Unit carbonated water outlet lines to insulated python carbonated water lines using BARBED CONNECTORS (item 3).

9

300614000

Image 13
Contents This Document Contains Important Information AURORAR10,000 Plus Cooling UnitTable of Contents Table of Contents cont’d WATER-TO-SYRUP ‘RATIO’OF Dispensed Drink TOO LOW or TOO Cooling Unit CO2 Inlet Line CO2 GAS Check ValveDispensed Product Produces Foam AS IT Leaves Dispensing Water Pump Motor Operates but Water Pump does not PumpCooling Unit Description General DescriptionCooling Unit Data System Theory of Operation Flow Diagram Typical Installation Identification of LOOSE-SHIPPED Parts Unpacking and InspectionSelecting Location Cooling UnitInstalling Cooling Unit Installing Remote Condenser Coil and FAN ASS’YRemote Condenser Coil and FAN ASS’Y Placing Cooling Unit in LocationConnecting Electrical Power Circuit to Cooling Unit Cooling Unit factory warranty Connecting Plain Water Inlet Supply Line to Cooling UnitConnecting CO2 Inlet Supply Line to Cooling Unit Preparing Cooling Unit for Operation Placing Cooling Unit in Operating PositionOperation Service internal components or electrical wiringInstalling Line Identification Label Dispensing Station AdjustmentsAdjusting Water Flow Rate Adjusting WATER-TO-SYRUP ‘‘RATIO’’ of Dispensed ProductCooling Unit Carbonator Motor Switch Cooling Unit Refrigeration Power SwitchCooling Unit Circulating Motor Switch Operating ControlsCleaning and Sanitizing AdjustmentsDaily PRE-OPERATION Check Replenishing CO2 SupplyCooling Unit Carbonator Maintenance Cooling Unit MaintenanceSanitizing Syrup Systems Cooling Unit AIR Intake and Exhaust FiltersCleaning CO2 GAS Check Valves Remote Condenser Coil and FAN ASS’Y MaintenanceCleaning Cooling Unit AIR Intake and Exhaust Filters Periodic CleaningPreparing Cooling Unit for SHIPPING, STORING, or Relocating Periodic InspectionChanging ICE Water Bath Remote Condenser Coil and FAN Assembly MaintenanceSee Figures 2 Parts Identification Primary CO2 Regulator LubricationSecondary CO2 Regulators Water Flow Rate Daily Cleaning of UnitWATER-TO-SYRUP ‘‘RATIO’’OF Dispensed Product Wash Syrup Systems Sanitizing POST-MIX Syrup SystemsSanitize Syrup Systems Flush Syrup SystemsWater Flush Syrup Systems Purge Water OUT of Syrup Systems Restore Operation CO2 GAS Check Valve Replenishing Syrup SupplySyrup Flavor Change Cleaning CO2 System GAS Check ValvesCooling Unit CO2 Inlet Line CO2 GAS Check Valve 300614000 Wiring Diagram WATER-TO-SYRUP ‘RATIO’ AdjustmentDispensed Drink TOO LOW or TOO HighCarbonation TOO LOW Dispensed ProductComes OUT Dispensing Valve Clear But Foams in CUP Only Carbonated Water aOnly Syrup Dispensed Only Carbonated WaterCarbonator Motor Warm Product BeingTemperature Sensing Operate Refrigeration PowerWater Pump Motor Operates but WaterContinuously but does Compressor OperatesNot Form Sufficient ICE Bank Not Form Sufficient ICE Wiring DiagramCondenser FAN Motor Not OperatingWarranty This page Left Blank Intentionally One Cornelius Place Anoka, Minnesota 612 800
Related manuals
Manual 52 pages 8.37 Kb

000 PLUS, 10 specifications

Cornelius 10,000 PLUS is a pioneering innovation in the beverage dispensing industry, designed to cater to the evolving needs of commercial establishments. This advanced system combines state-of-the-art technology with user-friendly features, making it a standout choice for restaurants, cafes, and bars aiming to enhance their beverage service.

One of the main features of the Cornelius 10,000 PLUS is its impressive capacity. With the ability to dispense a wide variety of beverages, including soft drinks, cocktails, and craft beers, the system supports a large volume of service, perfect for high-demand environments. The modular design allows for easy expansion, enabling businesses to add additional flavors or beverages as needed without major overhauls.

The technology behind the Cornelius 10,000 PLUS is equally impressive. It utilizes advanced cooling technology to ensure that beverages are served at the optimal temperature, enhancing the customer experience. The integrated touchless dispensing mechanism minimizes waste and ensures a hygienic experience, addressing growing concerns about cleanliness in food service environments. This technology also improves speed, allowing staff to serve customers more efficiently.

Another key characteristic of the Cornelius 10,000 PLUS is its digital integration capabilities. The system can be connected to a central management platform that tracks sales, inventory levels, and maintenance needs in real-time. This allows operators to optimize their beverage offerings based on customer preferences and reduces downtime through proactive maintenance alerts.

In addition to its performance features, the Cornelius 10,000 PLUS is designed with sustainability in mind. The system employs energy-efficient practices, reducing its environmental footprint while lowering operational costs. The materials used in construction are durable yet eco-friendly, ensuring longevity and less waste.

Overall, the Cornelius 10,000 PLUS stands out as an essential tool for any business looking to elevate its beverage service. With its combination of high capacity, cutting-edge technology, and sustainability features, it not only meets the demands of today’s fast-paced service environments but also positions establishments for future growth and success.