Kohler 24VDC, 6VSG, 36VDC, 48VDC manual 8Procedure to Set the Exerciser on the VSC Controller

Page 29

Genset ---->

System

System Voltage: 54.0V

Auto Start Volt: (V)

Auto Stop Load: (%)

Load Limit: (%)

Fuel Type:

Natual Gas

 

HOLD:

Next Exercise *

Next Exercise

HR:MN PM MM/DD/YY

HR:MN PM MM/DD/YY

 

HOLD:

Exercise Mode:

Exercise Mode:

Loaded

Loaded Full Sp

Unloaded Cycle

 

 

Loaded Full Sp

 

HOLD:

Exercise Freq:

Exercise Freq:

Weekly

Weekly/Bi-Weekly

Language:

English

Contrast:

50

tp6804

<---- Return

* If the exerciser has not been set, No Exercise Sch will be displayed.

Figure 3-8Procedure to Set the Exerciser on the VSC Controller

TP-6843 1/13

Section 3 VSC Controller Operation 29

Image 29
Contents TP-6843 1/13a VSCController Identification Product Identification InformationGenerator Set Identification Numbers Engine IdentificationTable of Contents Appendix a Abbreviations Table of ContentsScheduled Maintenance Accidental Starting Safety Precautions and InstructionsBattery Exhaust System Engine Backfire/Flash FireFuel System Hazardous Noise Use extreme care when handling, storing, and using fuelsHot Parts Heavy EquipmentList of Related Literature IntroductionEmission Information NameplateService Assistance Service Assistance TP-6843 1/13 Introduction Engine Descriptions and Service ViewsGenerator Set Enclosure AlternatorCarburetor Heater AccessoriesOnCue Generator Management System Programmable Interface Module PIMService Views 3Optional Communications Kit Components Theory of Operation Prestart ChecklistGenerator Set Operation Generator Set Operation Exercising the Generator SetShutdowns FaultsExercise Fault Message ShutdownSD Condition Check Resetting the Controller After a Fault Shutdown5Controller Fault Messages Generator Set Operation TP-6843 1/13 VSC Generator Set Controller Control and IndicatorsVSC Controller Operation Controller Keypad LED IndicatorsLCD Display 6Autopaging Displays, Automatic ModeBattery Charging Controller PowerChanging Settings Procedure to Change Settings7Changing Settings Setting the Exerciser at Controller Power-up Setting the ExerciserChanging the Exercise Settings Procedure to Set the Exerciser8Procedure to Set the Exerciser on the VSC Controller Main Menu VSC Controller MenusEngine Metering Menu Overview MenuCalibration Generator Metering MenuGenset Run Time Menu Generator Set Information MenuGenset System Menu System Parameters for Battery Bank ChargingNominal Voltage 24V 36V 48V System Voltage, VDC Adjusting the Display Contrast Setting the ExerciserNetworking Information Menus Date and Time MenuDhcp Networking Status SubmenuPassword Networking Configuration Submenu OnCue PasswordRbus Rbus Information25Remote Devices Submenu Remote Devices SubmenuProgrammable Interface Module PIM Status Menu Event Log Procedure to View Event HistoryVSC Controller Operation TP-6843 1/13 Scheduled Maintenance Scheduled MaintenanceFuel Service Schedule, 6VSG ModelsLubrication System Oil Change ProcedureLow Oil Pressure Shutdown Oil CheckSpark Plugs Resetting the Maintenance TimerPaper Element Service Air Cleaner ServicePrecleaner Service Cooling System Engine Starting BatteryLubricating System Storage ProcedureFuel System Cylinder LubricationBattery Fault Messages TroubleshootingController Service Access IntroductionProblem Possible Cause Recommended Action TroubleshootingAbdc Appendix a AbbreviationsSysteme international d’unites TP-6843 1/13 Appendix Appendix TP-6843 1/13 Page 2012, 2013 by Kohler Co. All rights reserved