3.9 Overview Menu

Overview ---->

Active Alert

1.2 h

 

(if any)

 

 

 

Genset Status

 

 

Standby

 

 

 

Generator:

54V

 

 

% Load

73%

 

 

Engine:

125F

 

 

Oil Pressure: OK

 

 

Battery:

13.3V

 

 

 

 

 

 

Engine Runtime:

 

 

 

100.6 h

 

 

Date:

02DEC2011

 

 

Time:

HR:MNpm

 

 

Next Exercise:

 

 

09:00p 09Dec2011

 

 

Next Maintenance:

 

 

150 h or Mar2012

 

 

SW Version:

 

 

4.06

 

 

 

 

<----

Return

Figure 3-10

Overview Menu

 

 

 

TP-6843 1/13

 

 

 

 

3.10 Engine Metering Menu

The engine metering menu displays engine status information as shown in Figure 3-11.This menu displays status information only. No settings can be changed from this menu.

Engine

---->

Eng Speed:

Metering

 

2300 R/min

 

 

Oil Pressure:

 

 

Switch: OK

 

 

Oil Temperature:

 

 

125 F

 

 

Battery:

 

 

13.3 V

 

 

<---- Return

 

 

tp6810

Figure 3-11Engine Metering Menu

Section 3 VSC Controller Operation 31

Image 31
Contents TP-6843 1/13a VSCEngine Identification Product Identification InformationController Identification Generator Set Identification NumbersTable of Contents Scheduled Maintenance Table of ContentsAppendix a Abbreviations Battery Safety Precautions and InstructionsAccidental Starting Exhaust System Engine Backfire/Flash FireFuel System Hazardous Noise Use extreme care when handling, storing, and using fuelsHot Parts Heavy EquipmentList of Related Literature IntroductionEmission Information NameplateService Assistance Service Assistance TP-6843 1/13 Alternator Descriptions and Service ViewsIntroduction Engine Generator Set EnclosureProgrammable Interface Module PIM AccessoriesCarburetor Heater OnCue Generator Management SystemService Views 3Optional Communications Kit Components Generator Set Operation Prestart ChecklistTheory of Operation Generator Set Operation Exercising the Generator SetExercise FaultsShutdowns Fault Message ShutdownSD Condition Check Resetting the Controller After a Fault Shutdown5Controller Fault Messages Generator Set Operation TP-6843 1/13 VSC Controller Operation Control and IndicatorsVSC Generator Set Controller Controller Keypad LED IndicatorsLCD Display 6Autopaging Displays, Automatic ModeProcedure to Change Settings Controller PowerBattery Charging Changing Settings7Changing Settings Procedure to Set the Exerciser Setting the ExerciserSetting the Exerciser at Controller Power-up Changing the Exercise Settings8Procedure to Set the Exerciser on the VSC Controller Main Menu VSC Controller MenusEngine Metering Menu Overview MenuCalibration Generator Metering MenuGenset Run Time Menu Generator Set Information MenuGenset System Menu System Parameters for Battery Bank ChargingNominal Voltage 24V 36V 48V System Voltage, VDC Adjusting the Display Contrast Setting the ExerciserNetworking Information Menus Date and Time MenuDhcp Networking Status SubmenuPassword Networking Configuration Submenu OnCue PasswordRbus Rbus Information25Remote Devices Submenu Remote Devices SubmenuProgrammable Interface Module PIM Status Menu Event Log Procedure to View Event HistoryVSC Controller Operation TP-6843 1/13 Scheduled Maintenance Scheduled MaintenanceFuel Service Schedule, 6VSG ModelsOil Check Oil Change ProcedureLubrication System Low Oil Pressure ShutdownSpark Plugs Resetting the Maintenance TimerPrecleaner Service Air Cleaner ServicePaper Element Service Cooling System Engine Starting BatteryCylinder Lubrication Storage ProcedureLubricating System Fuel SystemBattery Introduction TroubleshootingFault Messages Controller Service AccessProblem Possible Cause Recommended Action TroubleshootingAbdc Appendix a AbbreviationsSysteme international d’unites TP-6843 1/13 Appendix Appendix TP-6843 1/13 Page 2012, 2013 by Kohler Co. All rights reserved