Kohler 36VDC, 6VSG, 24VDC, 48VDC Accessories, Carburetor Heater, OnCue Generator Management System

Page 14

◦Backlit display with adjustable contrast for excellent visibility in all lighting conditions

•Scrolling system status display

◦Generator set status

◦Voltage and percent load

◦Engine temperature

◦Oil pressure

◦Battery voltage

◦Engine runtime hours

•Date and time displays

•Smart engine cooldown senses engine temperature

•Digital voltage regulation: ±1.0% RMS no-load to full-load

•Automatic start with programmed cranking cycle

•Programmable exerciser can be set to start automatically on any future day and time, and run every week or every two weeks

•Three exercise modes

•Front-access mini USB connector for SiteTech™ connection

•Integral Ethernet connector for Kohler® OnCue®

•Built-in 2.5 amp battery charger

•Remote two-wire start/stop capability

•Diagnostic messages

◦Displays diagnostic messages for the engine, generator, and programmable interface module (PIM)

◦Over 70 diagnostic messages can be displayed

•Maintenance reminders

•System settings

◦System voltage and percent load

◦Voltage adjustment

◦Measurement system, English or metric

•Programmable Interface Module (PIM) status displays

◦Input status (active/inactive)

◦Output status (active/inactive)

1.6 Accessories

The following optional accessories are offered for the 6VSG generator sets.

1.6.1Carburetor Heater

An optional carburetor heater is recommended for improved cold starting in locations where the ambient temperature drops below 0°C (32°F). The carburetor heater prevents condensation and carburetor icing. The heater requires a continuous source of AC power.

See the generator set Installation manual for more information.

1.6.2OnCue® Generator Management System

The Kohler® OnCue® Generator Management System allows monitoring and control of your 6VSG generator set from a personal computer located in your home or at other remote locations. OnCue® can also be configured to send email or text message notifications in the event of a generator set fault.

Note: Be sure to obtain the correct version of the OnCue® kit for the VSC controller.

OnCue® version 3.1 or higher is required for 6VSG generator sets.

1.6.3Programmable Interface Module (PIM)

The optional Programmable Interface Module (PIM) provides two programmable inputs and six programmable dry contact outputs for connection to customer-supplied equipment. The outputs are controlled by the VSC controller, and can also be controlled remotely using the OnCue® program.

The PIM is mounted in a NEMA 3R aluminum enclosure, which can be mounted indoors or outdoors. See the installation instructions provided with the PIM.

1.6.4Communications Kit

The optional communications kit includes the following factory-installed items:

•Interface board with factory-set inputs and outputs and customer connection terminal blocks

•Fuel pressure switch

•Enclosure intrusion alarm switch

14 Section 1 Descriptions and Service Views

TP-6843 1/13

Image 14
Contents VSC TP-6843 1/13aGenerator Set Identification Numbers Product Identification InformationController Identification Engine IdentificationTable of Contents Appendix a Abbreviations Table of ContentsScheduled Maintenance Accidental Starting Safety Precautions and InstructionsBattery Engine Backfire/Flash Fire Exhaust SystemUse extreme care when handling, storing, and using fuels Fuel System Hazardous NoiseHeavy Equipment Hot PartsIntroduction List of Related LiteratureNameplate Emission InformationService Assistance Service Assistance TP-6843 1/13 Generator Set Enclosure Descriptions and Service ViewsIntroduction Engine AlternatorOnCue Generator Management System AccessoriesCarburetor Heater Programmable Interface Module PIMService Views 3Optional Communications Kit Components Theory of Operation Prestart ChecklistGenerator Set Operation Exercising the Generator Set Generator Set OperationShutdowns FaultsExercise Resetting the Controller After a Fault Shutdown Fault Message ShutdownSD Condition Check5Controller Fault Messages Generator Set Operation TP-6843 1/13 VSC Generator Set Controller Control and IndicatorsVSC Controller Operation LED Indicators Controller Keypad6Autopaging Displays, Automatic Mode LCD DisplayChanging Settings Controller PowerBattery Charging Procedure to Change Settings7Changing Settings Changing the Exercise Settings Setting the ExerciserSetting the Exerciser at Controller Power-up Procedure to Set the Exerciser8Procedure to Set the Exerciser on the VSC Controller VSC Controller Menus Main MenuOverview Menu Engine Metering MenuGenerator Metering Menu CalibrationGenerator Set Information Menu Genset Run Time MenuSystem Parameters for Battery Bank Charging Genset System MenuNominal Voltage 24V 36V 48V System Voltage, VDC Setting the Exerciser Adjusting the Display ContrastDate and Time Menu Networking Information MenusNetworking Status Submenu DhcpNetworking Configuration Submenu OnCue Password PasswordRbus Information RbusRemote Devices Submenu 25Remote Devices SubmenuProgrammable Interface Module PIM Status Menu Procedure to View Event History Event LogVSC Controller Operation TP-6843 1/13 Scheduled Maintenance Scheduled MaintenanceService Schedule, 6VSG Models FuelLow Oil Pressure Shutdown Oil Change ProcedureLubrication System Oil CheckResetting the Maintenance Timer Spark PlugsPaper Element Service Air Cleaner ServicePrecleaner Service Engine Starting Battery Cooling SystemFuel System Storage ProcedureLubricating System Cylinder LubricationBattery Controller Service Access TroubleshootingFault Messages IntroductionTroubleshooting Problem Possible Cause Recommended ActionAppendix a Abbreviations AbdcSysteme international d’unites TP-6843 1/13 Appendix Appendix TP-6843 1/13 Page 2012, 2013 by Kohler Co. All rights reserved