DIGITAL VIDEO RECORDER

7Communication Setup

The following illustrates the intial setting of the COMMUNICATION SETUP menu.

COMMUNICATION SETUP

BAUD RATE

115,200

 

NETWORK ACCESS

ON

 

 

 

IP ADDRESS

0.

0.

0.

0

GATEWAY

0.

0.

0.

0

SUBNET MASK

0.

0.

0.

0

NETWORK

USER

ID

****

NETWORK

USER

PWD

****

PAN/TILT TYPE

 

SCC-421

MOVE=[ ///] SELECT=[ ] EXIT=[MENU]

BAUD RATE

Sets data transmission rate in RS-232C communication.

[4,800/9,600/19,200/38,400/115,200]

NETWORK ACCESS/IP ADDRESS/GATEWAY/SUBNET MASK

If the system is connected to a LAN, it can be controlled from the remote surveillance pro- gram installed on a remote PC. To connect to a LAN, set the NETWORK ACCESS to ON, and configure the IP ADDRESS, GATEWAY, SUBNET MASK, etc. to suit the user’s net- work environment. Then, connect the LAN Cable to the LAN Cable connection terminal on the back of the system and reboot the system. If at least one from the IP ADDRESS, GATEWAY, and SUBNET MASK is modified, the system must be rebooted to apply the modified setting to the system.

NETWORK USER ID/NETWORK USER PWD

In order to access the system through a LAN from a remote surveillance program installed on a remote PC, the user ID and password must be entered. At this time, the user ID and password entered match the ones set in the NETWORK USER ID and NETWORK USER PWD, you can connect to the system; otherwise, you cannot gain access. Both are 4-digit numbers and the initial set values are 0000.

PAN/TILT TYPE (Remote Control of Camera)

You can control the Pan/Tilt/Zoom function of a camera with the remote monitoring program installed in the remote PC through LAN. Then, you shall select the camera to be controlled. But, this remote control shall be applied only to SEC SCC-641/SCC-643(N/P) Cameras and SCC-421(N/P) Series Camera(C4201, C4203, C4301 and C4303) Camera which use the SAMSUNG Protocol. You can select the camera to be controlled by the remote monitoring program. Please refer to Remote Monitoring Program Use’s Manual for the detailed explanation of the remote monitoring program. [SCC-641/SCC-421]