Agilent Technologies E4400-90246 manuals
TV and Video > TV Converter Box
When we buy new device such as Agilent Technologies E4400-90246 we often through away most of the documentation but the warranty.
Very often issues with Agilent Technologies E4400-90246 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in TV Converter Box Agilent Technologies E4400-90246 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for TV Converter Box on our side using links below.
Agilent Technologies E4400-90246 Manual
168 pages 2.72 Mb
2 NoticeWhere to Find the Latest Information4 Contents30 Instrument Messages Introduction34 Instrument Messages96 What You Will Find in This Chapter What Are the Functional Tests? Functional Test Versus Performance Verification This chapter includes the following: 97 Before Performing a Functional Test98 Chapter 2 Functional Tests Test Equ ipment 98 TEST EQUIPMENT102 Amplitude Accuracy at 50 MHz107 Displayed Average Noise Level (DANL)Test Limits (with 0 dB input attenuation) 109 Frequency Readout Accuracy111 Frequency Response (Flatness)> 3 GHz to 6.6 GHz > 6.6 GHz to 22 Ghz > 22 GHz to 26.5 GHz > 26.5 GHz 113 115 Amplitude Linearity118 Second Harmonic Distortion (SHD)122 Displayed Average Noise Level123 Figure 4-1 Equipment Se tup124 Procedure (10 MHz to 500 MHz) E4401B and E4411B125 Procedure (501 MHz to 1.0 GHz) E4401B and E4411B126 Procedure (1.01 GHz to 1.5 GHz) E4401B and E4411B127 Procedure (10 MHz to 1 GHz) E4402B, E4403B, E4404B, E4405B, 128 Procedure (1.01 GHz to 2 GHz) E4402B, E4403B, E4404B, E4405B, 129 Procedure (2.01 GHz to 3.0 GHz) E4402B, E4403B, E4404B, E4405B, 131 Procedure (3.01 GHz to 6.0 GHz) E4404B, E4405B, E4407B, and E4408B132 Procedure (6.01 GHz to 6.7 GHz) E4404B133 Procedure (6.01 GHz to 12.0 GHz) E4405B, E4407B, and E4408B134 Procedure (12.01 GHz to 13.2 GHz) E4405B135 Procedure (12.01 GHz to 22 GHz) E4407B and E4408B136 Procedure (22.01 GHz to 26.5 GHz) E4407B and E4408B139 Frequency Readout Accuracy141 Marker Count Accuracy142 Chapter 4 Frequency Response (Flatness) (for this test) 142 Frequency Response (Flatness)146 Reference Level Accuracy151 Resolution Bandwidth Switching Uncertainty154 Chapter 4 Scale Fidelity (for this test) 154 Scale FidelitydB from Reference Level Minimum (dB)Maximum (dB) Chapter 4 157 Second Harmonic Spurious Responses (for this test) 157 Second Harmonic Spurious ResponsesModel Number Maximum 160 Chapter 4 Tracking Generator Level Flatness: Models E4401B and E4411B, Options 1DN and 1DQ (for this test) 160 Tracking Generator Level Flatness: Models E4401B and E4411B, Options 1DN and 1DQ163 Tracking Generator Level Flatness: E4402B, E4403B, E4404B, E4405B, E4407B and E4408B, Option 1DN
Also you can find more Agilent Technologies manuals or manuals for other TV and Video.