114 pages 1.31 Mb
2 416 420 4 4 421 2.6 Resetting to default values22 3 Manual operationManual operation DHW circuit mode selector switch (system Anl 9: underfloor heating circuit) In manual mode, frost protection is not guaranteed (> section 7.2). 23 4 Systems10 hydraulic schematics are available.Solar charging OFF Solar circuit pump OFF Solar circuit pump ON Systems 40 5 Functions of the heating circuit5.1 Weather-compensated control 5.1.1 Gradient characteristicLevel Min.flow temperature Max.flow temperature Set-back difference = Flow set point Level 41 4 4 4 442 5.1.2 4-point characteristicFig. 3 4-point characteristic Min. flow temperature Set-backdifference Flow temperature Outdoor temperature Return flow temperatureatpoints 2 and 3 indicates how much the flow temperature is reduced outside the times-of-use. The pa- rameters mark the upper and lower limits of the flow temperature. 42 Functions of the heating circuit 43 5.2 Fixed set point control5.3 Underfloor heating 44 5.4 Deactivation depending on outdoor temperature 5.4.1 OT deactivation value in rated operationOTdeactivation value in rated operation Outdoor temperature limit in summer mode 5.4.2 OT deactivation value in reduced operationOT deactivation value in reduced operation 5.4.3 Summer modeOutdoor temperature limit in summer mode 5.5 Delayed outdoor temperature adaptation 5.6 Remote operation 45 448 4 45.11 Potentiometer input 49 6 Functions of the DHW circuit 6.1 DHW heating in the storage tank system51 6.2 DHW heating in the storage tank charging system53 6.3 DHW heating with solar system (Anl 2, 3, 4, 5 und 9)Solarpump ON DHW temperature Solar charging OFF Solar pump OFF, 6.4 DHW heating in instantaneous heating system (Anl 6) 54 6.5 Circulation pump operation during storage tank charging6.6 Circulation over the heat exchanger 6.7 Intermediate heating operation (Anl 2, 3 and 9) 6.8 Parallel pump operation (Anl 2, 3 and 9) 55 6.9 Priority circuit (Anl 4, 5, 6, 7, 8 and 11)6.9.1 Reverse control 6.9.2 Set-back operationSet-back difference Priority in case of deviation 6.10 Forced charging of the DHW storage tank (Anl 2, 3, 5, 7, 8 and 9) 6.11 Thermal disinfection of the DHW storage tank 56 44 4 64 48.2 Collective error alarm 65 8.3 Temperature monitoringOperational faults Dial-upalso upon corrected fault 8.4 Error status registerThe error status register is used to indicate controller or system errors. In modem operation with 66 9 Communication9.1 Controller with RS-232-C port 67 4 4 4 4 44 4 72 4Minimum limit Maximum limit for the system Max. limit value Max. limit value for DHW Max. limit value for heating Max. limit value Maximum limit for heating 73 Maximum limit for the systemMaximum limit for heat- ing Limitingfactor Minimum limitthat appear in this order. The 9.5 Memory module 74 410 Installation 11 Electrical connection 76 477 4 498 4 4 4 44 4
Also you can find more Samson manuals or manuals for other Household Appliance.