- OPERATION MANUAL -

Programs

Manual

Store

8

Program selection

IFR: Automatic quick cooling program

Values setting not required. Can be activated with core probe only.

With the IFR program, there is no freezing on foodstuffs outer surface. (no risk of third-degree freezing).

The IFR program must not be used in negative quick cooling cycles.

Recommended: preset programs

Meat (core probe chilling)

Dairy (time-controlled chilling)

Pie (time-controlled chilling)

Stew (time-controlled chilling)

Fish (time-controlled chilling)

Poultry (time-controlled chilling)

Vegetables (time-controlled chilling)

Freezing Temp (with core probe freezing)

Freezing Time (time-controlled freezing)

User: 01 – 20 numbers available for programming according to the customers’ needs.

Cooling: this program cools the room before any chilling cycle.

Negative = QC with max. refrigerating air temp -13°F, max. core temp 0°F Positive Soft = QC with max. refrigerating air temp. +14°F, max. core temp. +36°F

Positive Hard = QC, 40% of time at -13°F, remaining time at +14°F, core temp. is set to +50°F. Suitable for big cuts of meat.

Automatic temp. regulation prior to ice formation on the surface.

Core

Time

If the core probe stays off, time-control turns on automatically.

Manual setting

Use the menu to manually configure core temperature values or the time and/or speed of the fans.

Positive = storing-cooling at + 36°F

Negative = storing-freezing at -8°F

Manual setting

Menu allows the user to set the products storing temp. after quick cooling.

Page 10
Image 10
2Wire 3185550/146127 manuel dutilisation Programs Manual Store, … Core … Time, Manual setting