2Wire 3185550/146127 manuel dutilisation Connection to Condensate Drain, Testing

Models: 3185550/146127

1 93
Download 93 pages 45.58 Kb
Page 30
Image 30

- INSTALLATION MANUAL -

CONNECTION TO CONDENSATE DRAIN

On certain models, a condensation discharge 1.2” diameter hose installation is necessary, ("SAREL" or any similar type). The current general and local regulations pertaining to drains are to be complied with. (pict.36)

Pict.36

The guarantee is voided and the Manufacturer will not be liable for any damage to appliances or operators arising from the non-compliance with and tamperings to any part of the appliance (electric, thermodynamic or hydraulic plant).

TESTING

Carry out the following checkings:

1)Ambient temperatures must be between 50[°F] and 90[°F].

2)Check power input.

3)Carry out at least one full quick cooling cycle

If the appliance was transported horizontally instead of a vertical position DO NOT START THE APPLIANCE IMMEDIATELY. WAIT FOR AT LEAST 4 HOURS BEFORE OPERATING.

28

Page 30
Image 30
2Wire 3185550/146127 manuel dutilisation Connection to Condensate Drain, Testing