Image 35

- INSTALLATION MANUAL -

 

Parameter

Description

 

Default

Default

min

MAX

 

 

(BCF...)

(BC...)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONFIGURATION

 

 

 

 

 

 

 

C01

Door input (0 de-activated; 1 activated)

 

1

1

0

1

 

 

C02

Door open polarity

 

0

0

0

1

 

 

C03

Door open alarm delay

 

2 min

2 min

0 min

60 min

 

C04

Activates buzzer (0 de-activated; 1 activated)

 

1

1

0

1

 

 

C05

Buzzer duration at the end of quick cooling cycle

 

10 sec

10 sec

0

600 sec

 

C06

Temperature difference in the first phase of needle insertion

 

13°F

45°F

0

140°F

 

test (0 = test excluded)

 

 

 

 

 

 

 

 

 

 

C07

Duration of the second phase of needle insertion test (0=test

 

56 sec

56 sec

0

600 sec

 

excluded)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Activates condenser probe

 

 

 

 

 

 

 

C08

0 = no probe

 

1

1

0

1

 

 

 

1 = probe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C09

Compressor stop delay due to door opening

 

30 sec

30 sec

0 sec

60 sec

 

C10

Control pressure alarm detection time

 

5 sec

5 sec

0 sec

60 sec

 

C11

High pressare digital input polarity

 

0

0

0

1

 

 

C12

Resistances starting SetPoint

 

23°F

23°F

14°F

68°F

 

 

ADJUSTMENT

 

 

 

 

 

 

 

R01

Compressor start/stop hysteresis

 

5°F

38°F

0°F

36°F

 

R02

Min. interval between 2 compressor starting

 

2 min

2 min

0 min

30 min

 

R03

Compressor start delay from card activation

 

0 sec

0 sec

0 sec

300 sec

 

R04

Compressor Duty-Cycle time with faulty room probe in storing

 

10 min

10 min

0 min

90 min

 

R05

Compressor ON time faulty room in pos. storing

 

3 min

3 min

0 min

90 min

 

R06

Compressor ON time with faulty room in neg. storing

 

8 min

8 min

0 min

90 min

 

R07

Needle min. temperature for starting quick cooling

 

158°F

158°F

32°F

194°F

 

R08

Compressor block temperature

 

194°F

194°F

32°F

212°F

 

R09

Compressor Protection function activation time

 

24 hour

24 hour

0 hour

240 hour

 

R10

Pulse duration

 

2 sec

2 sec

1 sec

10 sec

 

R11

Pause between pulses

 

8 sec

4 sec

1 sec

10 sec

 

R12

Number of pulses

 

3

3

1

20

 

 

R13

Temperature at the end of the Cooling cycle

 

-13°F

-13°F

-58°F

50°F

 

 

FANS

 

 

 

 

 

 

 

F01

Evaporator fans activation hysteresis

 

4°F

36°F

0°F

36°F

 

F02

Condenser fans activation hysteresis

 

4°F

36°F

0°F

36°F

 

F03

Evaporator fans activation SetPoint

 

41°F

41°F

-58°F

122°F

 

F04

Condenser fans activation SetPoint

 

59°F

59°F

-58°F

122°F

 

F05

Evaporator fans during defrost

 

0

0

0

1

 

 

0 = fans OFF; 1 = fans ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F06

Condenser fans during defrost

 

0

0

0

1

 

 

0 = fans OFF; 1 = fans ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F07

Fans stop time after defrost

 

1 min

1 min

0 min

30 min

 

F08

Condenser fans stop delay

 

30 sec

30 sec

0 sec

300 sec

 

 

Evaporator fans control during quick cooling:

 

 

 

 

 

 

 

F09

0 = fans always ON

 

0

0

0

1

 

 

 

1 = fans thermostated by evaporator temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evaporator fans control during storing:

 

 

 

 

 

 

 

F10

0 = fans in parallel with the compressor

 

0

0

0

1

 

 

 

1 = fans thermostated by evaporator temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F11

Evaporator fans block temperature

 

158°F

158°F

32°F

194°F

 

 

PRINT

 

 

 

 

 

 

 

PR1

Sampling time

 

10 min

10 min

1 min

60 min

 

 

VENTILATION SPEED (P.W.M.)

 

 

 

 

 

 

 

CF1

Evaporator fan min. speed

 

30

20

0

100

 

 

CF2

Evaporator fan min. speed selectable in a quick cooling cycle

 

50

50

0

100

 

 

 

 

 

 

 

 

33

 