- INSTALLATION MANUAL -

Parameter

Description

Default

Default

min

MAX

(BCF...)

(BC...)

 

 

 

 

 

 

 

 

 

 

 

I.F.R.

 

 

 

 

B01

Room thermostating temperature in the first phase

-48°F

-13°F

-58°F

122°F

B02

Under surface T control start temperature

41°F

86°F

-58°F

210°F

B03

First coefficient of the control relation

0

-2

-50

50

B04

Second coefficient of the control relation

0

16

-50

50

B05

Third coefficient of the control relation

-8

-8

-50

50

B06

Under surface T initial value determining the end of the first phase

30°F

34°F

-58°F

210°F

B07

Phase two formula coefficient

99

10

0

99

B09

Under surface t min. value allowed during the third phase

32°F

30°F

-58°F

210°F

B10

End of intelligent quick cooling core temperature

46°F

38°F

-58°F

210°F

B11

Delay from the positive result of the needle test for starting the

60 sec

60 sec

0 sec

99 sec

procedure to determine the end of the first phase

 

 

 

 

 

 

 

 

 

 

 

B12

First phase temperature detection time

30 sec

30 sec

0 sec

99 sec

B13

First phase min. duration

6 min

6 min

0 min

99min

B16

Defrost on starting intell. QC cycle (0=no 1=yes)

0

0

0

1

B17

Inhibition temperature

194°F

176°F

-58°F

210°F

B18

Room Set point in the event of automatic switch to time or

19°F

32°F

-58°F

210°F

temperature mode

 

 

 

 

 

 

 

 

 

 

 

B19

Max. duration possibile for intelligent QC process

999 min

150 min

1 min

999 min

B20

Under surface T safety value determining the end of the first

30°F

38°F

-58°F

210°F

phase

 

 

 

 

 

 

 

 

 

 

 

B21

First coefficient of the room thermostating curve (third phase)

10

-25

-90

99

B22

Second coefficient of the room thermostating curve (third

-50

-28

-90

99

phase)

 

 

 

 

 

 

 

 

 

 

 

B23

Storing activation at the end of intell. QC cycle

1

1

0

1

(0 = no; 1 = yes)

 

 

 

 

 

B24

Room thermostat Set-point in storing

36°F

36°F

-130°F

194°F

B26

Core temperature limit for the timer start

999

0

0

999

B27

Adjuster of fans speed in the third phase

99

0

0

99

B28

Cold pulse adjuster

10

0

0

99

 

COMMUNICATION

 

 

 

 

ADD

Device Address

1

1

1

147

 

Serial Control :

 

 

 

 

SC

0 = not activated

 

 

 

 

1 = print

1

1

0

2

 

 

2 = ModBus

 

 

 

 

 

 

 

 

 

 

MB1

BaudRate: 0 = 2400; 1 = 4800; 2 = 9600; 3 = 18200

2

2

0

3

MB2

Parity: 0 = no parity; 1 = odd; 2 = even

2

2

0

2

 

TYPE OF CYCLE

 

 

 

 

G01

Positive QC cycles only :

0

0

0

1

0 = Positive and Negative

 

1 = Positive only

 

 

 

 

CHANGING PARAMETERS

Press menu/esc to select the desired menu

Use the keys up and down to display

Service

Esc

Press enter to confirm your choice.

 

Service

0

The display shows

Password

(only the 1st time)

34

Page 36
Image 36
2Wire 3185550/146127 manuel dutilisation Changing Parameters, Display shows