- INSTALLATION MANUAL -
Parameter | Description | Default | Default | min | MAX | |
(BCF...) | (BC...) | |||||
|
|
|
| |||
|
|
|
|
|
| |
| I.F.R. |
|
|
|
| |
B01 | Room thermostating temperature in the first phase | 122°F | ||||
B02 | Under surface T control start temperature | 41°F | 86°F | 210°F | ||
B03 | First coefficient of the control relation | 0 | 50 | |||
B04 | Second coefficient of the control relation | 0 | 16 | 50 | ||
B05 | Third coefficient of the control relation | 50 | ||||
B06 | Under surface T initial value determining the end of the first phase | 30°F | 34°F | 210°F | ||
B07 | Phase two formula coefficient | 99 | 10 | 0 | 99 | |
B09 | Under surface t min. value allowed during the third phase | 32°F | 30°F | 210°F | ||
B10 | End of intelligent quick cooling core temperature | 46°F | 38°F | 210°F | ||
B11 | Delay from the positive result of the needle test for starting the | 60 sec | 60 sec | 0 sec | 99 sec | |
procedure to determine the end of the first phase | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
B12 | First phase temperature detection time | 30 sec | 30 sec | 0 sec | 99 sec | |
B13 | First phase min. duration | 6 min | 6 min | 0 min | 99min | |
B16 | Defrost on starting intell. QC cycle (0=no 1=yes) | 0 | 0 | 0 | 1 | |
B17 | Inhibition temperature | 194°F | 176°F | 210°F | ||
B18 | Room Set point in the event of automatic switch to time or | 19°F | 32°F | 210°F | ||
temperature mode | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
B19 | Max. duration possibile for intelligent QC process | 999 min | 150 min | 1 min | 999 min | |
B20 | Under surface T safety value determining the end of the first | 30°F | 38°F | 210°F | ||
phase | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
B21 | First coefficient of the room thermostating curve (third phase) | 10 | 99 | |||
B22 | Second coefficient of the room thermostating curve (third | 99 | ||||
phase) | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
B23 | Storing activation at the end of intell. QC cycle | 1 | 1 | 0 | 1 | |
(0 = no; 1 = yes) | ||||||
|
|
|
|
| ||
B24 | Room thermostat | 36°F | 36°F | 194°F | ||
B26 | Core temperature limit for the timer start | 999 | 0 | 0 | 999 | |
B27 | Adjuster of fans speed in the third phase | 99 | 0 | 0 | 99 | |
B28 | Cold pulse adjuster | 10 | 0 | 0 | 99 | |
| COMMUNICATION |
|
|
|
| |
ADD | Device Address | 1 | 1 | 1 | 147 | |
| Serial Control : |
|
|
|
| |
SC | 0 = not activated |
|
|
|
| |
1 = print | 1 | 1 | 0 | 2 | ||
| ||||||
| 2 = ModBus |
|
|
|
| |
|
|
|
|
|
| |
MB1 | BaudRate: 0 = 2400; 1 = 4800; 2 = 9600; 3 = 18200 | 2 | 2 | 0 | 3 | |
MB2 | Parity: 0 = no parity; 1 = odd; 2 = even | 2 | 2 | 0 | 2 | |
| TYPE OF CYCLE |
|
|
|
| |
G01 | Positive QC cycles only : | 0 | 0 | 0 | 1 | |
0 = Positive and Negative | ||||||
| 1 = Positive only |
|
|
|
|
CHANGING PARAMETERS
Press menu/esc to select the desired menu
Use the keys up and down to display
Service
Esc
Press enter to confirm your choice.
| Service | 0 |
The display shows | Password |
(only the 1st time)
34