Installing the Hardware

Table 19. Line card installation notes (Continued)

Minimum

Restrictions

Special Instructions

Firmware

 

 

 

 

 

SSR-SERC-04-AA

E8.3.0.0

CLI Setup

Enter the following command at the CLI before implementing any configurations.

1.Type the following from Enable mode to enter Configuration mode

Enable -> Configure #

2.You may now begin configuring ports on the SSR-SERC-04-AA. Refer to the Enterasys X-Pedition Command Line Interface Reference Manual for details.

Proper Boot Sequence

Firmware loads.

The control module for the chassis should indicate that the SSR-SERC-04-AA was detected and is operating correctly.

The Online LED will turn on and remain lit (no other LEDs should illuminate during module power-up).

Common Errors

The ER16-SERC-04-AA is not inserted properly or seated completely in the chassis

Connectors for the connected lines are not seated properly.

Helpful CLI Commands for Debugging

 

 

 

 

System show hardware

 

 

 

 

System show version

 

 

 

 

Port show port status se.x.y (where x is the chassis

 

 

 

 

 

slot that contains the line card and y is a specific port

 

 

 

 

 

number on the card).

 

 

 

 

System show bootlog

 

 

 

 

SSR-SERCE-04-AA

E8.3.0.0

CLI Setup

Proper Boot Sequence

 

 

Enter the following command at the CLI before

Firmware loads.

 

 

implementing any configurations.

• The control module for the chassis should indicate

 

 

 

 

 

 

1.

Type the following from Enable mode to enter

 

that the SSR-SERCE-04-A was detected and is

 

 

 

operating correctly.

 

 

 

Configuration mode

 

 

 

 

The Online LED will turn on and remain lit (no other

 

 

 

Enable -> Configure #

 

 

2.

You may now begin configuring ports on the

 

LEDs should illuminate during module power-up).

 

 

 

 

 

 

 

SSR-SERCE-04-A. Refer to the Enterasys

Common Errors

 

 

 

X-Pedition Command Line Interface Reference

 

 

 

Manual for details.

• The ER16-SERCE-04-A is not inserted properly or

 

 

 

 

 

 

 

 

 

seated completely in the chassis

 

 

 

 

• Connectors for the connected lines are not seated

 

 

 

 

 

properly.

 

 

 

 

Helpful CLI Commands for Debugging

 

 

 

 

System show hardware

 

 

 

 

System show version

 

 

 

 

Port show port status se.x.y (where x is the chassis

 

 

 

 

 

slot that contains the line card and y is a specific port

 

 

 

 

 

number on the card).

 

 

 

 

System show bootlog

 

 

 

 

 

 

76

Enterasys X-Pedition 8000/8600 Getting Started Guide

Page 88
Image 88
Enterasys Networks 8000/8600 manual Port show port status se.x.y where x is the chassis