Hardware Overview

AC Power Supply Specifications

The following table lists the specifications for the X-Pedition’s AC power supplies.

 

X-Pedition 8000

X-Pedition 8600

 

 

 

Dimensions

8.27 in. H x 17.25 W x 12.25 D

8.27 in. H x 17.23 W x 19.25 D

 

22.23 cm H x 43.82 W x 31.12 D

22.23 cm H x 43.82 W x 48.9 D

 

 

 

Weight

Pounds: 24Lbs

Pounds: 47 Lbs

 

Kilograms: 10.8 Kg

Kilograms: 21.2 Kg

 

 

 

AC Power

100-125 VAC, 5A maximum

100-125 VAC, 10A maximum

 

200-240 VAC, 3A maximum

200-240 VAC, 6A maximum

 

50/60 Hz

50/60 Hz

 

 

 

Output Wattage

390 Watts

780 Watts

At 3.4 V

70 Amps

140 Amps

At 5.1 V

25 Amps

50 Amps

At 12 Volts

2 Amps

4 Amps

 

 

 

Operating

Fahrenheit: 41oF to 104oF

Fahrenheit: 41oF to 104oF

Temperature

Centigrade: 5oC to 40oC

Centigrade: 5oC to 40oC

 

 

 

To ensure against equipment failure, you can install a redundant power supply. When two power supplies are active in the X-Pedition, they load share, each supply delivering approximately 50 percent of the current needed. Moreover, if one of the power supplies fails, the other power supply immediately assumes the entire load, thus preventing any system outage.

The AC power supply has a green status LED. When the LED is lit, the power supply is connected to an appropriate power source and is active. The status LED is lit when you switch the power supply on, not when you plug the power supply into a power source.

Enterasys X-Pedition 8000/8600 Getting Started Guide

17

Page 29
Image 29
Enterasys Networks 8000/8600 manual AC Power Supply Specifications, Pedition Dimensions