Installing the Hardware

Table 19. Line card installation notes (Continued)

Minimum

Restrictions

Special Instructions

Firmware

 

 

 

 

 

SSR-POS29-04

9.0.0.2

Note: If your system uses a redundant power

SSR-POS21-04

 

configuration or only one power supply, you

 

 

will not be able to support more than 5 cards

 

 

in the X-Pedition 8000 and 10 in the

 

 

X-Pedition 8600.

CLI Setup

Enter the following commands at the CLI before implementing any configurations.

1. Enable —>Configure —><Enter>.

2. Once you reach the configuration prompt, you can configure the SSR-POS21-04 or SSR-POS29-04 using CLI commands as described in the X-Pedition CLI manual. Enter the ? character to view the options available to you in configuration mode.

Proper Boot Sequence

Offline LED lights at power-up.

Port LEDs flicker briefly during system boot while ports initialize.

Online LED turns on once module is active.

Common Errors

The X-Pedition is not powered up.

The module is not properly seated in the slot.

Connectors on both ends of the cable are not properly engaged. The copper cable did not click into place or is not properly seated.

Helpful CLI Commands for Debugging

System show hardware

System show version

System show bootlog

SSR-POS39-02

9.0.0.2

Note: If your system uses a redundant power

SSR-POS31-02

 

configuration or only one power supply, you

 

 

will not be able to support more than 5 cards

 

 

in the X-Pedition 8000 and 10 in the

 

 

X-Pedition 8600.

CLI Setup

Enter the following commands at the CLI before implementing any configurations.

1. Enable —>Configure —><Enter>.

2. Once you reach the configuration prompt, you can configure the SSR-POS39-02 or SSR-POS31-02 using CLI commands as described in the X-Pedition CLI manual. Enter the ? character to view the options available to you in configuration mode.

Proper Boot Sequence

Offline LED lights at power-up.

Port LEDs flicker briefly during system boot while ports initialize.

Online LED turns on once module is active.

Common Errors

The X-Pedition is not powered up.

The module is not properly seated in the slot.

Connectors on both ends of the cable are not properly engaged. The copper cable did not click into place or is not properly seated.

Helpful CLI Commands for Debugging

System show hardware

System show version

System show bootlog

Enterasys X-Pedition 8000/8600 Getting Started Guide

75

Page 87
Image 87
Enterasys Networks 8000/8600 manual SSR-POS29-04 0.2 SSR-POS21-04