Problem

Solution

 

 

The control module is not active.

Check the power cable and the circuit to which

 

the power supply is connected.

 

If the power supply is working, make sure the

 

control module is inserted all the way into its

 

slot in the chassis and the captive screws are

 

screwed in. The control module must be in slot 0

 

or 1—not in a line card slot.

 

 

No line cards are active.

Check the power cable and the circuit to which

 

the power supply is connected.

 

 

A specific line card is inactive.

Make sure the line card is inserted all the way

 

into the chassis and the captive screws are

 

screwed in.

 

 

The chassis LEDs indicate activity but you

Make sure you have properly connected the

cannot tell what the X-Pedition is doing.

primary control module to a management

 

console and the console is powered on.

 

 

An older software version continues to boot

Use the procedure in Loading System Image

instead of the newer version on a PCMCIA

Software on page 96 to configure the X-Pedition

card or TFTP server.

to boot using newer software.

 

 

You are unable to access the configuration

Enter the enable command to access the Enable

commands in the CLI.

mode, then enter the configure command to

 

access the Configuration mode.

 

 

Configuration changes do not seem to be

Use the procedure in Activating the

taking effect.

Configuration Commands in the Scratchpad on

 

page 98 to activate the changes.

 

 

Configuration changes are not reinstated

Use the procedure in Saving the Active

after a reboot.

Configuration to the Startup Configuration File

 

on page 99 to save the configuration changes to

 

the Startup configuration file.

 

 