102 Enterasys X-Pedition 8000/8600 Getting Started Guide
The control module is not active. Check the power cable and the circuit to which
the power supply is connected.
If the power supply is working, make sure the
control module is inserted all the way into its
slot in the chassis and the captive screws are
screwed in. The control module must be in slot 0
or 1—not in a line card slot.
No line cards are active. Check the power cable and the circuit to which
the power supply is connected.
A specific line card is inactive. Make sure the line card is inserted all the way
into the chassis and the captive screws are
screwed in.
The chassis LEDs indicate activity but you
cannot tell what the X-Pedition is doing. Make sure you have properly connected the
primary control module to a management
console and the console is powered on.
An older software version continues to boot
instead of the newer version on a PCMCIA
card or TFTP server.
Use the procedure in Loading System Image
Software on page96 to configure the X-Pedition
to boot using newer software.
You are unable to access the configuration
commands in the CLI. Enter the enable command to access the Enable
mode, then enter the configure command to
access the Configuration mode.
Configuration changes do not seem to be
taking effect. Use the procedure in Activating the
Configuration Commands in the Scratchpad on
page 98 to activate the changes.
Configuration changes are not reinstated
after a reboot. Use the procedure in Saving the Active
Configuration to the Startup Configuration File
on page 99 to save the configuration changes to
the Startup configuration file.
Problem Solution