Installing the Hardware

3.Loosen captive screws. Use a phillips screwdriver to loosen the captive screws on the face of the module.

4.Remove the Control Module. Pull the Control Module out of the X-Pedition chassis and place it on an ESD-safe work area.The Control Module memory resides in slots P7 and P8. Figure 4 shows the location of the DIMM slots—slot P7 is the slot closest to the backplane.

Slot P7

Slot P8

Memory slots

MODULE

CONTROL

Mgmt

-

256

10/100

-CM4

 

 

SSR

 

 

Console

 

Figure 31. Install the DIMM in an X-Pedition memory slot

5.Insert the SSR-MEM-128 into an empty memory slot. Gently press the memory card in place and ensure that the card is completely seated in the slot.

Note: Slot P7 must contain the larger of the two DIMMs. If slot P7 already contains a 64MB DIMM, remove the 64MB DIMM and install the 128MB DIMM in slot P7. You may then install the 64MB DIMM in slot P8 for a total of 192MB installed on the Control Module.

If a 128MB DIMM already resides in slot P7, you need not remove it. Install the new 128MB DIMM in slot P8.

6.Align the backsheet of the Control Module between the card guides as shown in Figure 32.

Enterasys X-Pedition 8000/8600 Getting Started Guide

67

Page 79
Image 79
Enterasys Networks 8000/8600 manual Slot P7 Slot P8 Memory slots