Installing the Hardware

Firmware Image Requirements

Version 8.2.0.0 or later.

Default Module Settings

The CM4 comes with the baud rate on RS232 console port set to 9600.

Preparing the Module

You must install the PCMCIA card before you install the command module. You cannot add or remove a PCMCIA card while the unit is powered on.

Installing a Memory Upgrade

CAUTION: Before performing any upgrade or installation, ensure that you are properly “grounded” to avoid electrostatic discharge. The switch must be powered off before installing or replacing any module.

1.Determine how much memory is already installed on the Control Module. If you do not know how much memory is installed on the Control Module, enter the system show hardware command in Enable mode. The amount of memory is reported as the System Memory size. For example:

xp# system show hardware

 

Hardware Information:

 

System type:

X-Pedition 8600, Rev. A

CPU Module type:

CPU-Elan, Rev. 0

Processor:

R5000, Rev 3.0, 249.99 MHz

Icache size:

32 Kbytes, 32 bytes/line

Dcache size:

32 Kbytes, 32 bytes/line

CPU Board Frequency:

83.33 MHz

Switching Fabrics:

2 (Active = Fabric 1)

PCMCIA card:

No card present

System Memory size:

64 MBytes

Network Memory size:

8 MBytes

MAC Addresses

 

System:

00e063:fdd700

10BASE-T CPU Port:00e063:fdd701

Internal Use:

00e063:fdd702 -> 00e063:fdd73f

CPU Mode:

Active

Redundant CPU:

Not present

 

 

2.Power down the chassis.

Note: If the X-Pedition chassis contains a redundant Control Module, you do not need to power down the X-Pedition. You must, however, press the Hot Swap button before removing the Control Module.

66

Enterasys X-Pedition 8000/8600 Getting Started Guide

Page 78
Image 78
Enterasys Networks 8000/8600 manual Installing a Memory Upgrade, Firmware Image Requirements, Default Module Settings