Installing the Hardware

The following table lists the environmental specifications for the X-Pedition’s AC power supplies.

Operating Temperature

+5 to +40 °C (41 to 104 °F)

 

 

Non-operating Temperature

-30 to +73 °C (-22 to 164 °F)

 

 

Operating Humidity

15 to 90% (non-condensing)

 

 

Figure 24 shows an example of how to install an AC power supply. The procedure following the figure describes how to do this.

SSR-8

PWR

SSR-PS-8

100-125~5A

 

200-240~3A

 

50-60 Hz

Figure 24. Installing an AC power supply

AC Power Supply Installation Procedure

To install an AC power supply:

1.Ensure that the AC power supply is not powered on.

2.If a coverplate is installed over the power supply slot, use the #2 Phillips screwdriver to remove it. If you are replacing an AC power supply, unplug the power cable from the supply you are replacing, loosen the captive screws on the power supply’s front panel, then pull the supply out of the chassis.

3.Slide the AC power supply all the way into the slot, firmly but gently pressing to ensure that the pins on the back of the power supply are completely seated in the backplane.

Enterasys X-Pedition 8000/8600 Getting Started Guide

59

Page 71
Image 71
Enterasys Networks 8000/8600 manual SSR-8