Enterasys Networks 8000/8600 manual Rack Mount Installation

Models: 8000/8600

1 142
Download 142 pages 52.74 Kb
Page 69
Image 69

Installing the Hardware

Rack Mount Installation

You can install the X-Pedition in a standard 19-inch equipment rack. The X-Pedition chassis is equipped with front-mounting brackets. Figure 23 shows an example of how to install an X-Pedition 8600 chassis in an equipment rack.

SSR-8

Figure 23. Installing the X-Pedition 8600 chassis in an equipment rack

Note: Never attempt to rack mount the X-Pedition chassis unaided. Ask an assistant to help you hold the chassis.

Caution: To make lifting and holding the chassis easier, install the chassis before you install line cards or redundant control modules and power supplies.

To install the X-Pedition chassis in an equipment rack, use the following procedure. You need a #2 Phillips screwdriver to perform this procedure.

1.If the front-mounting brackets are already installed on the X-Pedition chassis, go to step 2. If not, do the following:

a.Align one of the mounting brackets over the corresponding holes in the side of the chassis. The mounting bracket is correctly positioned when the side with two open mounting holes is flush with the front of the chassis.

b.Use the #2 Phillips screwdriver and two of the supplied Phillips screws to attach the mounting bracket to the chassis.

c.Attach the other mounting bracket.

Enterasys X-Pedition 8000/8600 Getting Started Guide

57

Page 69
Image 69
Enterasys Networks 8000/8600 manual Rack Mount Installation, Installing the X-Pedition 8600 chassis in an equipment rack