Enterasys X-Pedition 8000/8600 Getting Started Guide 107
SSR-CM2B-64, SSR-CM3-128, and SSR-CM4-256
SSR-CM2B-64, SSR-CM3-128, and SSR-CM4-256
Connectivity Guidelines
The control modules have two ports for attaching management consoles to the X-Pedition.
A male DB-9 DCE port for direct serial connection from a terminal. You use this port to perform
basic setup, including setting up the X-Pedition for management through the network using CLI
or SNMP.
An RJ-45 10/100BASE-T DTE port for Telnet connection from a host on the network. The port
is configured for Media Data Interface (MDI). You use this port to manage the X-Pedition using
CLI or SNMP.
Connector Pin Assignments
The connector pins are assigned as follows:
Table 22. Control Module Recommended Cable Types and Specifications
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 100-ohm
UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP 100 m (328 ft) RJ-45
VART Ser ial
Connection Serial Cable DB9
Table 23. DB9-RS232 Console Port Pin Assignments
Pin Connection
1 Unused
2 TXD (transmit data)
3 RXD (receive data)
4 Unused
5 Ground
6 DTR (data terminal ready)
7 CTS (clear to send)
8 RTS (request to send)
9 Unused