Enterasys Networks 8000/8600 manual Splitting each source wire to two 12-gauge wires

Models: 8000/8600

1 142
Download 142 pages 52.74 Kb
Page 76
Image 76

Installing the Hardware

gauge negative (-) wires are connected to the X-Pedition 8600 DC power supply wiring block. See Figure 28.

From True

8-Gauge Wire (Green)

XP-8600

Ground

 

Wiring Lugs

 

Conductive

 

 

Splitter Block

 

From - 48-Volt

 

 

Source

12-Gauge Wire (Black)

 

6-Gauge Wire (Black)

-

 

 

 

12-Gauge Wire (Black)

-

 

 

 

Conductive

+

 

 

 

Splitter Block

+

From + 48-Volt￿

 

Source

 

 

6-Gauge Wire (Red)

12-Gauge Wire (Red)

 

 

12-Gauge Wire (Red)

 

Figure 28. Splitting each source wire to two 12-gauge wires

An alternate method of wiring the X-Pedition 8600 power supply is to use a single set of 8-AWG wires (+ and -) from the DC source, and then tie the X-Pedition 8600’s wiring lugs together: + to + and - to -. See Figure 29.

Both positive (+) and both negative (-) lugs are tied together with 8-gauge wire

8-Gauge Wire

To True

From Power

From Power

Ground

Source

 

 

Source +

 

(Green)

(Black)

(Red)

Figure 29. Tying X-Pedition 8600 DC supply lugs together

64

Enterasys X-Pedition 8000/8600 Getting Started Guide

Page 76
Image 76
Enterasys Networks 8000/8600 manual Splitting each source wire to two 12-gauge wires