Hardware Ov erview
40 Enterasys X-Pedition 8000/8600 Getting Started Guide
Number of Flows/Routes
Layer-2 Entries =512,000 (memory size = 32 MB)
Layer-3 Entries = 256,000 (memory size = 16 MB)
Physical Dimensions
Size: 27.94 cm H x 3.94 W x 19.68 D (11.00 in. H x 1.55 W x 7.75 D)
Weight: 1.4 kg (3.0 lbs)
Temperature
Operating: 41° to 104° F (5° to 40° C)
Storage: -22° to 164° F (-30° to 73° C)
Humidity
15% to 90% (non-condensing)
LEDs
Table 10. SSR-GTX32-04 and SSR-GTX32-02 LED Indicators
LED Condition Status
Online On (Green) The module is online and ready to receive, process, and send
packets (if configured to do so).
Offline On (Amber) The module is offline (powered down) and ready to hot swap.
Per-Port
Transmit Green The port transmitted a packet.
Amber The port transmitted a flow-control packet.
Per-Port
Receive Green The port received a packet.
Amber The port received a flow-control packet.
Per-Port
Link Green The port hardware detected a cable plugged into the port and
established a good link.
Off No link exists from the port.
Per-Port
Quality Green Auto-Negotiation completed successfully and the phy is attempting
to establish a link. This LED remains green while the link operates
with good signal-to-noise ratio.
Fast blink Low signal-to-noise ratio, close to data errors.
Slow blink Receive bit errors detected.
Off Auto-Negotiation is still in progress or the phy cannot receive
packet data.