Before setting to operation thoroughly clean the cooling cabinet with a suitable detergent or sodium bycarb dissolved in lukewarm water. Clean the appliance inside to remove any condensate caused by the Manufacturer's final testing.

Cooling and freezing speed depends on the following factors:

a)container shape, type and material;

b)whether container lids are used;

c)foodstuff features (density, water contents, fat contents);

d)starting temperature;

e)thermal conduction inside the foodstuffs

Positive /Negative quick cooling time depends on type of foodstuffs to be processed.

Full-speed cycle is recommended for high-density or large-sized foodstuffs. However, the following limits should never be exceeded : a 2” thickness for freezing and an 3” thickness for cooling (tab.2).

The low-speed cycle is suitable to process delicate foodstuffs, such as vegetables, creamy products, creamy desserts or low-thickness products.

We recommend making sure that any positive quick cooling cycles, to +38 [°F] to the core of the product, do not last over 180 minutes, and that negative quick cooling cycles, to 0 [°F] to the core of the product, do not last over 4 hours.

The processing room is to be pre-cooled before starting the positive and /or negative quick cooling cycle. Moreover, avoid covering the foodstuffs during the cycle, which would increase the cycle length.

We recommend using the core probe in order to have the exact core temperature reading. Do not stop the cycle before reaching a temperature of +38 [°F] during positive quick cooling and 0 [°F] during negative quick cooling.

Tab.2

Model

Max. output/cycle

 

Capacity

 

 

+160[°F] to+38[°F]

+160[°F] to +0[°F]

max shelves

pan size

BCF44244- BCB44244

44[lb]

24[lb]

5

 

12“x20“x1.5“

4

 

12“x20“x2.5“

 

 

 

 

 

 

BC40-4

40[lb]

-

5

 

12“x20“x1.5“

4

 

12“x20“x2.5“

 

 

 

 

 

 

BCF93558

 

93[lb]

55[lb]

14

 

12“x20“x1.5“

 

8

 

12“x20“x2.5“

 

 

 

 

 

 

BC80-8

 

80[lb]

-

14

 

12“x20“x1.5“

 

8

 

12“x20“x2.5“

 

 

 

 

 

 

 

 

 

 

 

26

 

12“x20“x1.5“

BCF11514

 

115[lb]

55[lb]

14

 

12“x20“x2.5“

 

13

 

18“x26“x1.5“

 

 

 

 

 

 

 

 

 

 

 

7

 

18“x26“x2.5“

 

 

 

 

 

26

 

12“x20“x1.5“

BC113-14

113[lb]

 

-

14

 

12“x20“x2.5“

 

13

 

18“x26“x1.5“

 

 

 

 

 

 

 

 

 

 

 

7

 

18“x26“x2.5“

 

 

 

 

 

32

 

12“x20“x1.5“

BCF22020

220[lb]

 

110[lb]

20

 

12“x20“x2.5“

 

16

 

18“x26“x1.5“

 

 

 

 

 

 

 

 

 

 

 

10

 

18“x26“x2.5“

4

Page 6
Image 6
2Wire 3185550/146127 manuel dutilisation Setting UP, Tab.2 Model Max. output/cycle Capacity