Table Top Installation Requirements

For table top or shelf mount installation of the ONline System Concentrator you must make sure the table or shelf can support 100 pounds (45 kg) for a fully loaded 17-slot concentrator. (The concentrator itself, fully loaded and with cable tray, weighs almost 75 pounds/34 kilograms.) The table/shelf also must be less than 6 feet (2 meters) from the nearest AC outlet.

To ensure proper airflow to the unit, you should leave at least 1.75" (4.45cm) of space below the concentrator (provided by the installed rubber feet) and by installing the cable tray below the concentrator.

Installation

Table 2-1 provides a quick description of the steps you must follow to install the ONline System Concentrator as well as reference to the section in this manual where the step is described. It is important that you perform the steps in the order indicated, noting that Step 3 is optional.

Table 2-1. Steps for Installing the ONline System Concentrator

Step

Action

Section

 

 

 

1

Install the cable tray into a

Installing the Cable Tray

 

rack or place it on a table

 

 

top.

 

 

 

 

2

Install the concentrator unit

Installing the ONline System

 

into a rack or place it on a

Concentrator

 

table top.

 

 

 

 

3

Install the backup power

Installing the Backup Power

 

supply in the concentrator.

Supply (Optional)”

 

 

 

2 - 6 ONline 17-Slot System Concentrator Installation and Operation Guide

Page 36
Image 36
3Com 5017C-LS, 5017C with load sharing installation and operation guide Table Top Installation Requirements