Setting the Autopartition Threshold Value

To set the maximum number of data collisions an installed management module allows on a port before it partitions the port, use the following management command:

SET MODULE {slot} AUTOPARTITION_THRESHOLD {31_coll} {63_coll} {127_coll} {255_coll}

You can set the autopartition threshold value to one of the following:

31

63 (default value)

127

255

The proper setting for most network environments is 63 (the default). The 10BASE-T specification suggests a minimum autopartition threshold value of 31, but 31 collisions may cause ports to partition more frequently than necessary.

Note: Autopartition values 127 and 255 are suggested only for debugging purposes, and are not recommended for use in live networks.

3 - 22 ONline Ethernet 24-Port 10BASE-T Module Installation Guide

Page 64
Image 64
3Com 5124M-TPCL manual Setting the Autopartition Threshold Value