Under some conditions a Port Activity LED may not light. Use the troubleshooting suggestions in Table 4-2 to help determine why this has occurred and to isolate the source of the problem.

Table 4-2. Troubleshooting Using the Port Activity LEDs

LED State

Possible Cause

Corrective Action

 

 

 

Off

There is no traffic

None.

 

received from the

 

 

segments (normal).

 

 

 

 

 

Hub power is off.

Check the Controller

 

 

Module Power LEDs.

 

 

 

 

The Activity LED has

Press the LED test button

 

burned out.

on the Controller Module.

 

 

 

 

A 24-Port Module port

Connect the cable to a

 

is faulty.

different port.

 

 

 

 

The module

Re-insert the 24-Port

 

connection to the

Module. If this fails to

 

backplane is bad.

correct the problem, try

 

 

another concentrator slot.

 

 

 

 

The 24-Port Module is

Try a different 24-Port

 

faulty.

Module.

 

 

 