1 ï

Instruction 3MSpeedglasSL Welding Shield

BEFORE WELDING

For your own protection read these instructions carefully before using the Speedglas SL welding shield.

The complete assembly is illustrated in figure A:1.

Adjust the welding shield according to your individual requirements. (see figure B:1–B:3).

The Speedglas SL welding shield is designed to be used in arc welding applications where shade 8-12 is recommended.

Shade number should be chosen according to table on page 185.

The unit is suitable for all arc welding processes such as MMA, MIG, MAG, TIG and Plasma Arc.

The Speedglas SL welding shield gives permanent protection (shade 12) against harmful UV- and IR-radiation, regardless of whether the filter is in the light or dark state or whether the autodarkening function is operational. The welding filter has two photo sensors that react independently and cause the filter to darken when a welding arc is struck.

Two lithium batteries are used as the power source. (3V CR2032)

The Speedglas SL welding shield is equipped with an auto on function and will automatically switch off when not used.

Note!

Use only with original Speedglas brand spare parts such as inner and outer protection plates according to the part numbers provided in these instruc- tions. The use of substitute components might impair protection and may invalidate claims under the warranty or cause the shield to be non compli- ant with Protection Classifications and approvals.

Note!

The Speedglas SL welding shield is not suitable for laser welding, laser cut- ting or gas welding/cutting (e.g. oxyacetylene). The Speedglas SL welding shield is designed for all uses except heavy duty overhead welding/cutting operation due to the risk of burns from falling molten metal.

Markings

The welding filter is marked with the shade range.

The eye and face protection classification is made according to EN 379, EN 166, EN 169 and EN 175.

6

Page 6
Image 6
3M manual Instruction 3M Speedglas SL Welding Shield, Before Welding, Markings

SL specifications

3M SL, also known as 3M Science of Safety, is an innovative product line that blends advanced materials science with cutting-edge technologies to enhance personal safety and workplace productivity. Designed for various industries, including healthcare, construction, and manufacturing, 3M SL focuses on delivering solutions that prioritize user protection without compromising comfort.

One of the standout features of 3M SL products is their exceptional breathability. Utilizing state-of-the-art filtration technology, 3M SL mask designs allow for optimal airflow while effectively filtering out harmful particles. This is particularly crucial in high-risk environments where prolonged usage is required. The specialized materials used in these masks contribute to a lightweight feel, ensuring that users can wear them for extended periods without discomfort.

Another significant characteristic of 3M SL is its commitment to standard compliance. The products are rigorously tested to meet or exceed rigorous safety standards, such as NIOSH and EN regulations. This compliance not only assures users of their effectiveness in protecting against airborne contaminants but also emphasizes 3M's dedication to maintaining the highest quality assurance levels.

In addition to these features, 3M SL employs innovative technologies, such as the use of advanced electrostatic filters. These filters generate a charged static field that attracts and captures smaller particles more efficiently than traditional filtering methods. This technology enhances protection while reducing breathing resistance, further contributing to user comfort.

3M SL also emphasizes versatility in its product offerings. From surgical masks designed for healthcare professionals to respirators suitable for industrial applications, the range caters to a diverse audience. This adaptability ensures that varying levels of protection and comfort are available to meet the specific needs of different users.

Ergonomic designs play a crucial role in the 3M SL range. With features such as adjustable nose clips and soft inner materials, the products are tailored to fit a variety of face shapes, enhancing both comfort and efficacy. This thoughtful design approach minimizes gaps that could allow unfiltered air to enter, maximizing protection.

Lastly, 3M SL embraces sustainability through responsible material sourcing and manufacturing processes, making it a forward-thinking option in personal protection. By investing in sustainable practices, 3M is not only committed to user safety but also to environmental stewardship.

In conclusion, 3M SL stands out in the crowded market of personal protective equipment by leveraging advanced materials science, innovative technologies, and ergonomic design to deliver superior comfort and safety. The combination of breathability, compliance with safety standards, and versatile applications makes 3M SL a leading choice for anyone seeking reliable protection in challenging environments.