System Management Commands 4

To open a connection, the switch first selects the server that successfully sent mail during the last connection, or the first server configured by this command. If it fails to send mail, the switch selects the next server in the list and tries to send mail again. If it still fails, the system will repeat the process at a periodic interval. (A trap will be triggered if the switch cannot successfully open a connection.)

Example

Console(config)#logging sendmail host 192.168.1.19

Console(config)#

logging sendmail level

This command sets the severity threshold used to trigger alert messages.

Syntax

logging sendmail level level

level - One of the system message levels (page 4-42). Messages sent include the selected level down to level 0. (Range: 0-7; Default: 7)

Default Setting

Level 7

Command Mode

Global Configuration

Command Usage

The specified level indicates an event threshold. All events at this level or higher will be sent to the configured email recipients. (For example, using Level 7 will report all events from level 7 to level 0.)

Example

This example will send email alerts for system errors from level 3 through 0.

Console(config)#logging sendmail level 3

Console(config)#

logging sendmail source-email

This command sets the email address used for the “From” field in alert messages.

Syntax

logging sendmail source-email email-address

email-address- The source email address used in alert messages. (Range: 1-41 characters)

Default Setting

None

4-49