3 Configuring the Switch

CLI – Specify the hostname, location and contact information.

Console(config)#hostname R&D 5

4-24

Console(config)#snmp-server location WC 9

4-114

Console(config)#snmp-server contact Ted

4-113

Console(config)#exit

 

 

Console#show system

 

4-60

System Description: 8*10GE L2 Switch

 

System OID String: 1.3.6.1.4.1.259.6.10.76

 

System Information

 

 

System Up Time:

0 days, 4 hours, 5 minutes, and 56.31 seconds

System Name:

[NONE]

 

System Location:

[NONE]

 

System Contact:

[NONE]

 

MAC Address (Unit1):

00-0C-DB-21-11-33

 

Web Server:

Enabled

 

Web Server Port:

80

 

Web Secure Server:

Enabled

 

Web Secure Server Port:

443

 

Telnet Server:

Enable

 

Telnet Server Port:

23

 

Authentication login:

local RADIUS none

 

Jumbo Frame:

Disabled

 

POST Result:

 

 

DUMMY Test

1 ................. PASS

UART Loopback Test ........... PASS

DRAM Test .................... PASS

Timer Test

................... PASS

PCI Device

1 Test ............ PASS

I2C Bus Initialization ....... PASS

Switch Int

Loopback Test ..... PASS

Done All Pass.

Console#

Displaying Switch Hardware/Software Versions

Use the Switch Information page to display hardware/firmware version numbers for the main board and management software, as well as the power status of the system.

Field Attributes

Main BoardSerial Number – The serial number of the switch.Number of Ports – Number of built-in ports.Hardware Version – Hardware version of the main board.Internal Power Status – Displays the status of the internal power supply.Management SoftwareEPLD Version – Version number of EEPROM Programmable Logic Device.Loader Version – Version number of loader code.Boot-ROM Version – Version of Power-On Self-Test (POST) and boot code.Operation Code Version – Version number of runtime code.Role – Shows that this switch is operating as Master (i.e., stand alone).

3-10