Command Reference

 

 

 

 

Parameter

Description

 

 

 

 

-Ppriority

The execution priority of the entered

 

Default value is

command. Assignable priority values are

 

restricted to a range from 1 (highest) to 32

 

15.

 

(lowest) inclusive.

 

 

 

 

 

 

-Rretries

Number of retries the CLI software attempts if

 

Default value is

a time-out is returned by the API software.

 

 

 

3.

 

 

 

 

 

-Ttimeout

Amount of time (in seconds) the API software

 

Default value is

waits for status from VolServ before returning

 

a time-out to the CLI software. Total wait time

 

120 seconds.

 

for a command is (retries plus 1) multiplied by

 

 

 

 

time-out value.

 

 

 

 

-Vprognum

RPC program number for VolServ.

 

Default value is

 

 

300016.

 

 

 

 

Return Codes

• 0 - The vsconnectqry command is successfully

 

processed.

 

-1 - An error is detected by either the CLI software or the

 

API software.

 

• >0 - An error is detected by VolServ. The returned exit code

 

corresponds to the error code given by VolServ.

Examples

Step 1.

Successful enterprise query. Requests VolServ to

 

 

return a list of the client internet addresses

 

 

associated with enterprise identifier 3.

vsconnectqry 3

Commands

601356 Rev A

Command Reference

2-41

Page 77
Image 77