ADIC 601356 manual Step, vsping, VolServ is available

Models: 601356

1 192
Download 192 pages 39.58 Kb
Page 158
Image 158
vsping

Command Reference

Parameter

Description

 

 

-h

Requests help for the entered command.

 

When the Help option is specified, no

 

command line processing is performed.

 

An exit code of 0 is returned to the client when

 

the Help option is specified.

 

 

-Hhostname

Host name of the VolServ server.

 

The default host name is the host name of the

 

computer where the CLI command is run.

 

 

-Vprognum

RPC program number for VolServ.

Default value is

 

300016.

 

 

 

Return Codes

• 0 - The vsping command is successfully processed.

 

-1 - An error is detected by either the CLI software or the

 

API software.

 

• >0 - An error is detected by VolServ. The returned exit code

 

corresponds to the error code given by VolServ.

Examples

Step 1.

Successful request, VolServ is available.

 

 

Requests VolServ to acknowledge receipt of the Ping

 

 

request.

 

 

 

 

 

vsping

 

 

Step 2.

 

 

 

Output returned:

VolServ is available.

2-122