vsdismount

Command Reference

vsdismount

Parameters

Dismounts media from a drive.

For automated libraries, VolServ checks to see that the media is ejected from the drive by the storage subsystem. If the media is not ejected from the drive, the vsdismount request fails and VolServ returns a failure status to the client. However, if the media is ejected from the drive, VolServ tells the library robotics to move the media from the drive pickup point to a bin within the library system. A successful return code is returned to the client after the media movement is completed.

For manual libraries, a dismount notice is sent to the appropriate library’s console display for action. An operator dismounts the specified media and then notifies VolServ that the media dismount is complete. VolServ returns a successful return code to the client only after the operator confirms the dismount is complete.

vsdismount mediaid

vsdismoun-d driveid

[-l lockid] [-u usagetime] [-e errorcount] [ -Ih ]

[ -Hhostname ] [ -Ppriority ] [ -Rretries ]

[ -Ttimeout ] [ -Vprognum ]

2-44