Command Reference

 

 

 

 

Parameter

Description

 

 

 

 

-Ppriority

The execution priority of the entered

 

Default value is

command. Assignable priority values are

 

restricted to a range from 1 (highest) to 32

 

15.

 

(lowest) inclusive.

 

 

 

 

 

 

-Rretries

Number of retries the CLI software attempts if

 

Default value is

a time-out is returned by the API software.

 

 

 

3.

 

 

 

 

 

-Ttimeout

Amount of time (in seconds) the API software

 

Default value is

waits for status from VolServ before returning

 

a time-out to the CLI software. Total wait time

 

120 seconds.

 

for a command is (retries plus 1) multiplied by

 

 

 

 

time-out value.

 

 

 

 

-Vprognum

RPC program number for VolServ.

 

Default value is

 

 

300016.

 

 

 

 

Return Codes

• 0 - The vsdriveqry command is successfully processed.

 

-1 - An error is detected by either the CLI software or the

 

API software.

 

• >0 - An error is detected by VolServ. The returned exit code

 

corresponds to the error code given by VolServ.

Examples

Step 1.

Successful drive query. Requests VolServ to return

 

 

information on every drive known to the VolServ

 

 

system.

vsdriveqry -a

Commands

601356 Rev A

Command Reference

2-49

Page 85
Image 85
ADIC 601356 manual Vsdriveqry command is successfully processed