Index

bottle head assembly, 165

proportioning valve, high-spped, 199

seal insert tool, 18

control module, 162

PTFE frit, 18, 108

seal wash, 38, 198, 199

cover, 167

PTFE lubricant, 121

seal wash, when to use, 38

damaged, 17

pump configuration, 65

seal wear counters, 207

foam, 169

pump drive, 143

seal, alternative material, 39

hydraulic path, 166

pump head assembly, 172

seals, 112

leak handling, 171

pump head missing, 75

security lever, 22, 98

light pipes, 170

pump head with seal wash, 174

selection valve failed, 63

main assemblies, 160

pump piston, 32

serial number

missing, 17

pump seals, 112

entered on control module, 248

outlet ball valve, 176

purge valve, 108

serial number change with control

pump head, 172

purge valve frit, 32, 108

module, 248

pump head with seal wash, 174

purging the pump, 28

servo restart failed, 74

pump housing and main assemblies,

 

setable flow range, 254

161, 162

R

setting

sheet metal kit, 168

rear of pump, 23

baudrate, 225

solvent cabinet, 164

reassembling the pump head, 121

data bit, 225

parts identification

recommended pH range, 254

forced cold-start, 226

cables - LAN cables, 195

remote

parity, 226

performance specification, 254

signal distribution, 221

RS 232C communication, 224

pH range, 254

remote interface, 220

stay resident, 226

physical specifications, 16

removing

setting the address, 224

piston, 32, 115, 200

pump head assembly, 110

sheet metal kit, 168

piston chamber, 199

the foam, 128

shipping containers, 17

plateaus, leak test, 93

the top cover, 128

shut-down, 49

power consideration, 14

repairs, 102

simple repairs, 98, 102

power consumption, 16

replacing the foam, 156

site requirements, 14

power cords, 14

replacing the top cover, 156

snap fasteners, 25

power light pipe, 170

restart without cover, 59

solvent bottle, 17

power supply, 147

results, pressure test, 86

solvent cabinet, 32, 164

power supply indicator, 46

RS-232

solvent filters

power supply lamp, 46

cable kit to PC, 194

checking, 35

power switch, 22

RS-232C communication settings, 224

cleaning, 35

power-input socket, 14

RS-232C connection table, 222

prevent blocking, 35

prerun condition, 46

RS-232C interface, 220

solvent information, 34

pressure, 199

run mode, 46

solvent inlet filters, 32

pressure above upper limit, 61

running the leak test, 90

solvent tubes, 19

pressure below lower limit, 62

running the pressure test, 84

solvent tubes, degasser, 17

pressure converter, 210

 

sonic bath, 106

pressure pulsation, 40, 203, 254

S

specification

pressure range, 39

safety

main power supply, 229

pressure sensor readings, 23

standards, 16

performance, 254

pressure test, 44, 82

safety light switch, 127, 130, 156

physical, 16

pressure, operating range, 254

sapphire piston, 200

spectrum

priming

screwdriver pozidriv #1, 128, 138, 141,

range, 238

with a pump, 28, 29

143, 147, 152, 154, 156

stack configuration, 20

with a syringe, 28, 36

seal

front view, 20

with the pump, 36

wear-in, 113

rear view, 21

269

Page 269
Image 269
Agilent Technologies 1100 Series manual 269

1100 Series specifications

Agilent Technologies 1100 Series is a highly regarded lineup of high-performance liquid chromatography (HPLC) systems designed to meet the demanding needs of laboratories in various fields including pharmaceuticals, environmental testing, and food safety. Known for its versatility, reliability, and advanced technology, the 1100 Series has established itself as a benchmark for analytical performance.

One of the standout features of the Agilent 1100 Series is its modular architecture. This design allows users to configure the system according to specific analytical requirements. The components such as pumps, detectors, and autosamplers can be mixed and matched to create a tailored solution, ensuring maximum efficiency and optimal performance. This modularity also facilitates easy upgrades and maintenance, significantly extending the life cycle of the instrument.

At the heart of the 1100 Series is its advanced pumping technology. The system utilizes precise, high-pressure pumps that ensure a consistent flow rate and excellent reproducibility, essential for accurate quantification of analytes. The binary and quaternary pump options provide flexibility in method development, enabling users to perform gradient elution with ease.

The Agilent 1100 Series also boasts a range of detectors, including UV/VIS, fluorescence, and refractive index detectors. Each detector is designed to enhance sensitivity and specificity, enabling the detection of a wide array of compounds. The UV/VIS detector, in particular, is known for its reliable performance and user-friendly interface, which simplifies method setup and data analysis.

Another critical aspect of the 1100 Series is its autosampler. The system's autosamplers provide high throughput and automatic sample handling, which significantly reduces human error and increases productivity. The intelligent design allows for temperature control and reliable sample injection, ensuring optimal results.

In terms of software, the 1100 Series is supported by Agilent’s OpenLAB software, which offers an intuitive platform for method development, data acquisition, and analysis. This software integrates seamlessly with the HPLC hardware, making it easier for scientists to manage workflows and maintain compliance with regulatory requirements.

Overall, the Agilent Technologies 1100 Series represents a significant advancement in liquid chromatography, bringing together ideal characteristics such as modularity, precision, versatility, and sophistication. Its commitment to innovation and quality makes it a preferred choice for laboratories seeking reliable analytical solutions.