Agilent Technologies 1100 Series manual Error Messages

Models: 1100 Series

1 272
Download 272 pages 29.99 Kb
Page 6
Image 6

Contents

Power Supply Indicator

46

 

Pump Status Indicator

46

 

Error Messages

47

 

 

 

Timeout 48

 

 

 

 

 

Shut-Down

49

 

 

 

 

Remote Timeout

50

 

 

 

Synchronization Lost

51

 

 

Leak 52

 

 

 

 

 

Leak Sensor Open

53

 

 

Leak Sensor Short

54

 

 

Compensation Sensor Open

55

Compensation Sensor Short

56

Fan Failed

57

 

 

 

 

Open Cover

58

 

 

 

 

Restart Without Cover

59

 

Zero Solvent Counter

60

 

 

Pressure Above Upper Limit

61

Pressure Below Lower Limit

62

Pressure Signal Missing

63

 

Missing Pressure Reading

64

Pump Configuration

65

 

 

Valve Fuse

66

 

 

 

 

Inlet-Valve Fuse 67

 

 

 

Valve Failed

68

 

 

 

 

Motor-Drive Power 69

 

 

Encoder Missing

70

 

 

 

Inlet-Valve Missing

71

 

 

Temperature Out of Range 72

Temperature Limit Exceeded

73

Servo Restart Failed

74

 

 

6

Page 6
Image 6
Agilent Technologies 1100 Series manual Error Messages

1100 Series specifications

Agilent Technologies 1100 Series is a highly regarded lineup of high-performance liquid chromatography (HPLC) systems designed to meet the demanding needs of laboratories in various fields including pharmaceuticals, environmental testing, and food safety. Known for its versatility, reliability, and advanced technology, the 1100 Series has established itself as a benchmark for analytical performance.

One of the standout features of the Agilent 1100 Series is its modular architecture. This design allows users to configure the system according to specific analytical requirements. The components such as pumps, detectors, and autosamplers can be mixed and matched to create a tailored solution, ensuring maximum efficiency and optimal performance. This modularity also facilitates easy upgrades and maintenance, significantly extending the life cycle of the instrument.

At the heart of the 1100 Series is its advanced pumping technology. The system utilizes precise, high-pressure pumps that ensure a consistent flow rate and excellent reproducibility, essential for accurate quantification of analytes. The binary and quaternary pump options provide flexibility in method development, enabling users to perform gradient elution with ease.

The Agilent 1100 Series also boasts a range of detectors, including UV/VIS, fluorescence, and refractive index detectors. Each detector is designed to enhance sensitivity and specificity, enabling the detection of a wide array of compounds. The UV/VIS detector, in particular, is known for its reliable performance and user-friendly interface, which simplifies method setup and data analysis.

Another critical aspect of the 1100 Series is its autosampler. The system's autosamplers provide high throughput and automatic sample handling, which significantly reduces human error and increases productivity. The intelligent design allows for temperature control and reliable sample injection, ensuring optimal results.

In terms of software, the 1100 Series is supported by Agilent’s OpenLAB software, which offers an intuitive platform for method development, data acquisition, and analysis. This software integrates seamlessly with the HPLC hardware, making it easier for scientists to manage workflows and maintain compliance with regulatory requirements.

Overall, the Agilent Technologies 1100 Series represents a significant advancement in liquid chromatography, bringing together ideal characteristics such as modularity, precision, versatility, and sophistication. Its commitment to innovation and quality makes it a preferred choice for laboratories seeking reliable analytical solutions.