Manuals
/
Agilent Technologies
/
Household Appliance
/
Water Pump
Agilent Technologies
manual Agilent 1100 Series Quaternary Pump
Models:
1100 Series
1
3
272
272
Download
272 pages
29.99 Kb
1
2
3
4
5
6
7
8
<
>
Specification
Install
Error codes
Schematics
Warranty
Maintenance
Pump Configuration
Repairing the Pump
Diagnostics and Tests
Setup View
Page 3
Image 3
Agilent 1100 Series Quaternary Pump
Reference Manual
Page 2
Page 4
Page 3
Image 3
Page 2
Page 4
Contents
Reference Manual
Warranty
Agilent 1100 Series Quaternary Pump
This Book
Status Indicators
Installing the Pump
Error Messages
Leak Test
Pressure Test
Overview of Main Assemblies
Exchanging Internal Parts 127
Introduction to the Quaternary Pump
Cable Overview 181
Control Module Screens for the Quaternary Pump
Contents
Contents
Installing the Pump
Power Consideration
Power Cords
Site Requirements
Environment
Bench Space
Physical Specifications Type Comments
Damaged Packaging
Delivery Checklist
Quaternary Pump Checklist Description Quantity
Unpacking the Quaternary Pump
Accessory Kit Contents Quaternary Pump
Accessory Kit Contents-Vacuum Degasser
Recommended Stack Configuration Front View
Optimizing the Stack Configuration
Stack containing the autosampler
Installing the Quaternary Pump
Preparations
Parts required
Rear of Quaternary Pump
Front panel is turned off
Settings, see Setting the 8-bit Configuration Switch on
Removing the Front Cover
Flow Connections of the Quaternary Pump
Two wrenches 1/4-5/16 inch for capillary connections
Toxic or hazardous solvents are used
Flow Connections of the Quaternary Pump
Mcgv
Priming and Purging the System
Priming with the Pump
Activity Solvent Comments
Optimizing Performance
Hints for Successful Use of the Quaternary Pump
Procedure on
Solvent Information
Cleaning the Solvent Filters
Prevent Blocking of Solvent Filters
Checking the Solvent Filters
Operational Hints for the Vacuum Degasser
Operational Hints for the Vacuum Degasser
Operational Hints for the Multi Channel Gradient Valve Mcgv
When to use the Continuous Seal Wash Option
When to Use Alternative Seals
Optimize the Compressibility
Compensation Setting
Solvent pure Compressibility 10-6/bar
Optimize the Compressibility Compensation Setting
Troubleshooting and Test Functions
Troubleshooting and Test Functions
Location of Status Indicators
Status Indicators
Pump Status Indicator
Power Supply Indicator
Error Messages
Timeout
Shut-Down
Remote Timeout
Synchronization Lost
Leak
Leak sensor in the quaternary pump has failed open circuit
Leak Sensor Open
Leak sensor in the quaternary pump has failed short circuit
Leak Sensor Short
Compensation Sensor Open
Compensation Sensor Short
Fan Failed
Open Cover
Replace the top cover and foam
Restart Without Cover
Zero Solvent Counter
Pressure Above Upper Limit
Pressure Below Lower Limit
Pressure Signal Missing
Missing Pressure Reading
Pump Configuration
Valve Fuse
Inlet-Valve Fuse
Valve 0 Failed valve a
Valve Failed
Motor-Drive Power
Encoder Missing
Inlet-Valve Missing
Temperature Out of Range
Temperature Limit Exceeded
Position for restarting
Servo Restart Failed
Broken plunger
Pump Head Missing
Index Limit
Index Adjustment
Index Missing
Stroke Length
Initialization Failed
Wait Timeout
Description
Pressure Test
Pressure Test
Positioning the blank nut
Inside the flow path definitely will cause the test to fail
Running the Pressure Test
Running the test from the ChemStation
Running the test from the Control Module
Running the Pressure Test
If the pressure test fails
Evaluating the Results
Potential Causes of Pressure Test Failure
Potential Cause Pump Corrective Action
Potential Cause Autosampler
Leak Test
Half of the ramp
Start the test and follow the instructions
Tools required ¼ inch wrench Parts and materials
Running the Leak Test
Leak Test Pressure Profile
No Pressure increase at Ramp
Potential Cause Corrective Action
Potential Cause
First plateau positive, second and third plateau negative
All plateaus negative
First plateau negative, second plateau positive
Ramp 3 does not reach limit
Third plateau negative pressure drop 2 bar/min
Evaluating the Results
Repairing the Pump
Exchanging Internal Parts
Simple Repairs
Cleaning the Quaternary Pump
Using the ESD Strap
Using the ESD Strap
Overview
Overview of Repair Procedures
Simple Repair Procedures Typical Frequency
Simple Repair Procedures
Exchanging the Valve Cartridge
Exchanging the Active Inlet Valve
Cartridge or the Active Inlet Valve
Removing the Active Inlet Valve
Replacing the Active Inlet Valve
105
Exchanging the Outlet Ball Valve
107
Purge Valve
Exchanging the Purge Valve Frit or
Exchanged
Head Assembly
Removing and Disassembling the Pump
Damage the pump drive
111
Tools required
Exchanging the Pump Seals and Seal Wear-in Procedure
When required
For the seal wear-in procedure
Seal Wear-in Procedure
Will definetely damage the normal phase application seals
0905-1420
Exchanging the Pump Seals and Seal Wear-in Procedure
Parts
Exchanging the Plungers
Installing the Continuous Seal Wash Option
117
Lifetime of the seals
119
Exchanging the Wash Seals
Exchanging the Wash Seals
Mm hexagonal key Pump head grease
Reassembling the Pump Head Assembly
Reassembling the Pump Head Assembly
Procedure
Exchanging the Multi-Channel Gradient
Valve Mcgv
124
125
Exchanging the optional Interface Board
Exchanging Internal Parts
Remove the solvent cabinet from the quaternary pump
Removing the Top Cover and Foam
129
130
Exchanging the Low Pressure Pump Main Board LPM Board
LPM Board Connectors
Mcgv
Connector Description
WA R NI N G T E
Entering the Type Command using the Control Module
Entering the Type Command
Entering the Type Command using the ChemStation
Entering the Serial Number using the Control Module
Entering the Serial Number
Entering the Serial Number using the ChemStation
Replacing the Quaternary Pump’s Firmware
Exchanging the Damper
Disconnect the two damper capillaries
Reconnect the two damper capillaries
Fan and arrow on the bottom foam
Exchanging the Fan
142
Part required
Exchanging the Pump Drive
144
Reinstall the pump head and fix with the two screws
Tubings and cables
Preparation for this procedure
Exchanging the Power Supply
148
149
150
Exchanging the Power Supply
Exchanging the Leak Sensor
153
Part required
Exchanging the Status Light Pipe
Assembling the Main Cover
Cover kit contains all parts, but it is not assembled
May not be able to remove the side from the top part
Procedure Located in its correct place
Replacing the Top Cover and Foam
Tools required Screwdriver Pozidriv #1
Location of foam in the light switch
158
Parts and Materials
Overview of Main Assemblies
Overview of Main Assemblies
Repair Parts Pump Housing and Main Assemblies Front View
Repair Parts Pump Housing and Main Assemblies Rear View
Control Module B-version
Solvent Cabinet
Solvent Cabinet Parts Description Part Number
Solvent Cabinet Parts
Bottle Head Assembly
Bottle-Head Assembly Parts Description Part Number
Bottle-Head Assembly Parts
Hydraulic Path
Hydraulic Path Description Part Number
Hydraulic Flow Path of the Quaternary Pump
Cover Parts
Cover Parts Description Part Number
Cover Parts
Sheet Metal Kit
Sheet Metal Kit Description Part Number
Sheet Metal Kit
Foam Parts
Foam Parts Description
Foam Parts
Power and Status Light Pipes
Power and Status Light Pipes Description Part Number
Power and Status Light Pipes
Leak Parts
Leak Parts Description Part Number
Leak Parts
Pump Head Assembly Description Part Number
Pump Head Assembly
173
Pump Head Assembly with Seal Wash Option
175
Outlet Ball Valve Assembly
Outlet Ball Valve Assembly Description Part Number
Outlet Ball Valve Assembly
Purge Valve Assembly
Purge-Valve Assembly Description Part Number
Purge-Valve Assembly
Active Inlet Valve Assembly Description Part Number
Active Inlet Valve Assembly
Tools and Accessories Description Part Number
Accessory Kit G1311-68705
Seal Wash Option Description Part Number
Seal Wash Option Kit
Cables Overview Type Description Part Number
Cable Overview
Contacts
Cables
Auxiliary
External
Analog Cables
Agilent 1100 to 3390/2/3 Integrators
Agilent 1100 to 3394/6 Integrators
Agilent 1100 to General Purpose
Agilent 1100 to BNC Connector
Agilent 1100 to 3390 Integrators
Remote Cables
Agilent 1100 to 3394 Integrators
Agilent 1100 to 3392/3 Integrators
Agilent 1100 to 3396 Series II / 3395A Integrators
Agilent 1100 to 3396A Integrators
Agilent 1100 to 3396 Series III / 3395B Integrators
TTL
Connector Pin Active 01046-60202 Agilent
BCD Cables
Agilent 1100 to 3396 Integrators
Auxiliary Cable
Can Cable
Agilent 1100 Series Degasser to general purposes
Connector Pin G1103-61611 Color
External Contact Cable
Agilent 1100 Series Interface Board to general purposes
Agilent 1100 module to PC RS-232 Cable Kit 34398A
RS-232 Cable Kit
Recommended Cables
LAN Cables
196
Introduction to the Quaternary Pump
Overview of the Quaternary Pump
Introduction to the Quaternary Pump
199
How does the Pump Work?
201
Quaternary Pump Details
How Does Compressibility Compensation Work?
How Does Variable Stroke Volume Work?
Electrical Connections
205
Instrument Layout
Seal Wear Counters
Early Maintenance Feedback EMF
EMF Counters
Pump Liquimeter
Setting the EMF Limits
Using the EMF Counters
Low pressure pump main board LPM, see
Electronics
Low-Pressure Pump Main Board LPM
Electronic Fuses
Onboard Battery
Block Diagram Signal Explanations
Fan Drive
212
Interconnection Diagram Low Pressure Main Board LPM
Firmware Description
Resident System
Main System
Firmware Updates
Optional Interface Boards
BCD Board
2110-0004
LAN Boards Agilent Order Number Supported networks
LAN Board
Agilent 1100 Series Interfaces
Agilent 1100 Series Interfaces
Regulations, see Cable Overview on
Analog Signal Output
Gpib Interface
Can Interface
RS-232C
APG Remote Interface
Pin Signal Description
APG Remote Signal Distribution
RS-232C Connection Table
Pin Direction Function
RS-232 Cable
Bit Configuration Switch
Setting the 8-bit Configuration Switch
Module Address Binary Address
Gpib Default Addresses
Communication Settings for RS-232C Communication
Default Addresses for Agilent Series 1100 Modules
Baudrate Settings
Forced cold start has been completed
Forced Cold-Start Settings
Stay Resident Settings
Parity Settings
Stay Resident Settings
Main Power Supply MPS Block Diagram
Main Power Supply Assembly
Main Power Supply Specifications
230
Control Module Screens for the Quaternary Pump
Menu
Major keys on the Agilent 1100 Control Module
Information/help
Enter
Screens available from the Analysis screen
Setup View
Pump ON/OFF
Settings
Screens available from the Analysis screen
Fillings to their current state
Analog -Status
Screens available from the Analysis screen
241
System screen
Screens available from the System screen
System
Screens available from the Records screen
Counters after exchanging parts that are subject to wear
Screens available from the Records screen
247
Maintenance logbook
Screens available from the Records screen
Schematics
Tests screen
Diagnostics and Tests
Pressure Test
Specifications
Type Specification
Performance Specifications
255
256
Warranty Statement
Limitation of Warranty
All Chemical Analysis Products
Responsibilities of the Customer
Limitation of Remedies and Liability
Days Onsite
Responsibilities of Agilent Technologies
Safety Information
General
Operation
Safety Symbols
Safety Symbols
Symbol Description
WA R NI N G CA U T IO N
Lithium Batteries Information
Radio Interference
Sound Emission
Manufacturer’s Declaration
Solvents
Flow Cell
Agilent Technologies on Internet
Index
268
269
270
Page
This Book