Agilent Technologies 1100 Series manual Index

Models: 1100 Series

1 272
Download 272 pages 29.99 Kb
Page 267
Image 267

Index

A

accessory kit, 18 accessory kit, degasser, 19 active inlet valve, 103, 178 active inlet valve drive, 210 air flow, 141

algae growth, 35 alternative seal material, 39

ambient non-operating temperature, 16 ambient operating temperature, 16 analog output, 255

APG remote connector, 23, 220 ASIC - application-specific integrated

circuit, 210

assembling the main cover, 155 AUTO mode, 203

AUX output, 23

B

ball-screw drive, 200 battery, 211, 263 baudrate setting, 225 BCD board, 126, 216 bench space, 15 blank nut, 84 blockage, 69

board connectors, 132 bottle, 17

bottle head assembly, 17, 165 buffer, 198

buffer application, 32 buffer solution, 123, 198

C cable

CAN, 18, 23 GPIB, 23 interface, 22 power, 17 remote, 18 signal, 18

CAN cable, 23 CAN interface, 219

capillary, pump to injection device, 18 changing solvents, 28 ChemStation, 23

cleaning the pump, 99 compensation sensor open, 55

compensation sensor short, 56

zero solvent counter, 60

composition precision, 254

error condition, 46

composition range, 254

error message

compressibility compensation, 40, 202,

wait timeout, 81

254

error messages, 44, 47

condensation, 15

compensation sensor open, 55

connecting tubes, 19

compensation sensor short, 56

connections, flow, 25

encoder missing, 70

continuous seal wash, 38, 198

fan failed, 57

control module, 162

ignition without cover, 58

EMF, 245

index adjustment, 77

firmware update, 246

index limit, 76

serial number change of MWD, 248

index missing, 78

tests, 251

initialization failed, 80

counter, EMF, 207

inlet valve fuse, 67

counter, seal wear, 207

inlet-valve missing, 71

cover parts, 167

leak, 52

 

leak senso open, 53

D

leak sensor short, 54

damaged parts, 17

missing pressure reading, 64

damper, 138

motor drive power, 69

damping unit, 138

pressure above upper limit, 61

data bit settings, 225

pressure below lower limit, 62

default address settings, 224

pump configuration, 65

degasser, 17

pump head missing, 75

delay volume, 20, 202

selection valve failed, 63

delivery checklist, 17

servo restart failed, 74

description, leak test, 88

shut-down, 49

description, pressure test, 82

stroke length, 79

dimensions, 16

synchronization lost, 50

disassembling the pump head assem-

temperature limit exceeded, 73

bly, 110

temperature out of range, 72

dual piston in-series design, 199

timeout, 48

 

errror

E

unknown error 2055, 60

early maintenance feedback (EMF),

ESD strap, 100

206

ESD wrist strap, 18

electrical connections

exchanging

descriptions of, 204

active inlet valve, 102, 103

electronic fuses, 211

damper, 138

electrostatic discharge (ESD), 98

fan, 141

EMF

interface board, 126

on control module, 245

internal parts, 98, 127

EMF counters, 207

leak sensor, 152

EMF limits, 208

LPM Board, 131

encoder missing, 70

multi channel gradient valve

environment, 14, 15

(MCGV), 123

error

outlet ball valve, 102, 106

267

Page 267
Image 267
Agilent Technologies 1100 Series manual Index

1100 Series specifications

Agilent Technologies 1100 Series is a highly regarded lineup of high-performance liquid chromatography (HPLC) systems designed to meet the demanding needs of laboratories in various fields including pharmaceuticals, environmental testing, and food safety. Known for its versatility, reliability, and advanced technology, the 1100 Series has established itself as a benchmark for analytical performance.

One of the standout features of the Agilent 1100 Series is its modular architecture. This design allows users to configure the system according to specific analytical requirements. The components such as pumps, detectors, and autosamplers can be mixed and matched to create a tailored solution, ensuring maximum efficiency and optimal performance. This modularity also facilitates easy upgrades and maintenance, significantly extending the life cycle of the instrument.

At the heart of the 1100 Series is its advanced pumping technology. The system utilizes precise, high-pressure pumps that ensure a consistent flow rate and excellent reproducibility, essential for accurate quantification of analytes. The binary and quaternary pump options provide flexibility in method development, enabling users to perform gradient elution with ease.

The Agilent 1100 Series also boasts a range of detectors, including UV/VIS, fluorescence, and refractive index detectors. Each detector is designed to enhance sensitivity and specificity, enabling the detection of a wide array of compounds. The UV/VIS detector, in particular, is known for its reliable performance and user-friendly interface, which simplifies method setup and data analysis.

Another critical aspect of the 1100 Series is its autosampler. The system's autosamplers provide high throughput and automatic sample handling, which significantly reduces human error and increases productivity. The intelligent design allows for temperature control and reliable sample injection, ensuring optimal results.

In terms of software, the 1100 Series is supported by Agilent’s OpenLAB software, which offers an intuitive platform for method development, data acquisition, and analysis. This software integrates seamlessly with the HPLC hardware, making it easier for scientists to manage workflows and maintain compliance with regulatory requirements.

Overall, the Agilent Technologies 1100 Series represents a significant advancement in liquid chromatography, bringing together ideal characteristics such as modularity, precision, versatility, and sophistication. Its commitment to innovation and quality makes it a preferred choice for laboratories seeking reliable analytical solutions.