2-25
Application Tutorials
Tutorial 7: Default and Custom Mask or Limit Line Testing
Stretch, Reduce, or Move the Mask
11 To stretch, reduce or move the mask by press: 
prev menu, scale X|Y or offset X|Y 
Add a Mask Margin
12 Press the left-side Masks softkey. 
13 To automatically align the mask to a display ed signal, press: 
MASK ALIGN 
14 To add mask margins, press: 
MASK MARGIN and enter the % of needed margin 
msk mar ON|OFF ON, prev menu 
Begin a Test 
15 Display the Masks/Limits menu by pressing: 
MENU, page 1 of 2, Analyze, masks, limits  
16 Select the trace for testing by pressing: 
trace:  
17 If trace violations are to be counted as errors, press: 
count TRC|DOT TRC  
18 If measurement point violations are to be counted as errors, press: 
count TRC|DOT DOT  
19 To select when testing should stop, press: 
end on: 
20 If you want testing to stop after a set number of errors, press: 
#errors ON|OFF ON desired number of errors  
21 If you want testing to stop after a set number of traces, press: 
#traces ON|OFF ON desired number of traces  
22 To begin testing, press: 
test ON|OFF ON