DISPlay Commands

The self-test does not require operator interaction beyond sending the *TST? query.

ExampleOUTPUT 728;"*TST?"

ENTER 728; A$

*WAI

Syntax

*WAI

Definition

The wait-to-continue command prevents the

 

instrument from executing any further

 

commands, all pending operations are

 

completed.

Example

OUTPUT 728;"*WAI"

8.4 DISPlay Commands

:DISPlay:BRIGhtness

Syntax

:DISPlay:BRIGhtness <wsp> <value>

Description This command sets the brightness of the display. The brightness is a floating point number in the range 0 (least bright) to 1 (brightest). There are seven possible levels of intensity. The value input for the brightness is rounded to the closest of these seven values.

The default brightness is 1.

:DISPlay:BRIGhtness?

Syntax:DISPlay:BRIGhtness?