INTRODUCTION
The IS system is a commercial and security video intercom system especially designed for applications in facilities such as office buildings, factories, schools, hospitals, and prisons. Installed separately from conventional
PRECAUTIONS
|
|
| General Prohibitions | Prohibition to Dismantle the Unit |
|
| Prohibition on Subjecting the Unit to Water | ||||
|
|
|
|
| |||||||
|
|
|
|
| |||||||
|
|
| General Precautions |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 7. | Do not install the unit in any of the following locations. Fire, | |
|
|
|
| WARNING |
|
| |||||
|
|
|
|
|
|
|
| electric shock, or unit trouble could result. | |||
Negligence could result in death or serious injury. |
|
|
|
| * Places under direct sunlight or places near heating | ||||||
|
|
|
| equipment that varies in temperature. | |||||||
1. | Do not dismantle or alter the unit. Fire or electric shock could |
|
|
|
| * Places subject to dust, oil, chemicals, hydrogen sulfide (hot | |||||
|
|
| result. |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| spring). | |
|
|
|
|
|
|
|
|
|
|
| |
|
| 2. | Keep the unit away from water or any other liquid. |
|
|
|
| * Places subject to moisture and humidity extremes, such as | |||
|
|
|
|
|
| ||||||
|
|
|
|
|
| ||||||
|
|
| Fire or electric shock could result. |
|
|
|
| bathrooms, cellars, greenhouses, etc. | |||
3. | High voltage is present internally. Do not open the case. |
|
|
|
| * Places where the temperature is quite low, such as inside a | |||||
|
|
| Electric shock could result. |
|
|
|
| refrigerated area or in front of an air conditioner. | |||
4. | Do not connect any |
|
|
|
| * Places subject to steam or smoke (near heating or cooking | |||||
|
|
|
| surfaces). | |||||||
|
|
| terminals. Also, do not install two power supplies in parallel to a |
|
|
| |||||
|
|
| single input. Fire or damage to the unit could result. |
|
|
|
| * Where noise generating devices such as dimmer switches or | |||
5. | Do not connect any terminal on the unit to an AC power line. |
|
|
|
| inverter electrical appliances are closeby. | |||||
|
|
|
| * Locations subject to frequent vibration or impact. | |||||||
|
|
| Fire or electric shock could result. |
|
|
|
| ||||
6. | Do not use power supply with a voltage other than specified. |
|
| 8. | Do not put high pressure on the LCD. If fractured, injury could | ||||||
|
|
| Fire or electric shock could result. |
|
|
|
| result. | |||
7. | Do not put any metal or flammable material into the unit |
|
| 9. | If the LCD is punctured, do not allow contact with the liquid | ||||||
|
|
|
| crystal inside. Inflammation could result. If necessary, gargle | |||||||
|
|
| through the openings. Fire, electric shock, or unit trouble could |
|
|
|
| ||||
|
|
|
|
|
|
| your mouth and clean your eyes or skin with clear water for at | ||||
|
|
| result. |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| least 15 minutes, and consult your doctor. | |
8. | The unit is not |
|
|
| |||||||
| 10. | Do not use the handset when you perform a call test or check | |||||||||
|
|
| or flammable materials. Fire or explosion could result. |
|
|
|
| the chime volume, otherwise it may cause damage to your ear. | |||
9. | Existing wiring such as chime wiring, etc. may contain high |
|
|
|
| Be sure to use the | |||||
|
|
| voltage AC electricity. Damage to the unit or electric shock |
|
| 11. | Be sure to perform a call test or check the chime volume with | ||||
|
|
| could result. Wiring and installation should be done by a |
|
|
|
| the handset on the hook. If you operate the hook switch with | |||
|
|
| qualified technician. |
|
|
|
|
|
|
| the handset on your ear, a sudden call etc. may arrive causing |
|
|
|
|
|
|
|
|
|
|
| damage to your ear. |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| CAUTION |
|
|
|
|
| ||
|
|
|
|
|
|
|
| GENERAL PRECAUTIONS | |||
Negligence could result in injury to people or damage to property. |
|
|
| ||||||||
|
| 1. Keep the unit more than 1m (3.3') away from radio or TV set. | |||||||||
1. | Do not install or make any wire terminations while power |
|
|
| 2. Keep the intercom wires more than 30cm (12'') away from AC | ||||||
|
|
| supply is plugged in. It can cause electrical shock or damage to |
|
| ||||||
|
|
| the unit. |
|
|
|
|
|
| result. | |
2. | When mounting the unit on a wall, install the unit in a |
|
|
| 3. Install the unit in an area that will be accessible for future | ||||||
|
|
| convenient location, but not where it could be jarred or |
|
|
| inspections, repairs, and maintenance. | ||||
|
|
| bumped. Injury could result. |
|
|
| 4. As to other manufacturer’s devices (such as sensor, detectors, | ||||
3. | Before turning on power, make sure wires are not crossed or |
|
|
| door releases) used with this system, comply with the | ||||||
|
|
| Specifications and Warranty conditions that the manufacturers or | ||||||||
|
|
| shorted. If not, fire or electric shock could result. |
|
|
| |||||
|
|
|
|
|
| venders present. | |||||
4. | For power supply, use Aiphone power supply model or model |
|
|
| |||||||
|
|
| 5. If the unit is down or does not operate properly, unplug the power | ||||||||
|
|
| specified for use with system. If |
|
|
| supply or turn off the POWER switches. | ||||
|
|
| fire or malfunction could result. |
|
|
| 6. When | ||||
|
|
|
|
|
|
|
|
|
| ||
5. | On products with ground terminals, connect to an earth ground. |
|
| This does not indicate a malfunction. | |||||||
|
|
| Fire or malfunction could result. |
|
|
| 7. The unit case may become a warm with use, but this is not a unit | ||||
6. | Do not put anything on the unit or cover the unit with cloth, etc. |
|
|
| malfunction. | ||||||
|
|
| Fire or unit trouble could result. |
|
|
| 8. If it is used close to a cellular phone, the unit may malfunction. | ||||
|
|
|
|
|
|
|
|
|
| 9. The unit can be damaged if dropped. Handle with care. | |
|
|
|
|
|
|
|
|
|
|
|
|
4