Advanced Control Suite User’s Guide
only 2 pairs of wires are available in the cabling plant. By default, this property is set to Enable. To disable Ethernet@Wirespeed, change the setting to Disable.
Note
This parameter is available only for copper devices and is not displayed for the
–Disable. Disables Ethernet@Wirespeed.
–Enable (default). Enables Ethernet@Wirespeed
Flow Control. The Flow Control property enables or disables the receipt or transmission of PAUSE frames. PAUSE frames enable the network adapter and a switch to control the transmit rate. The side that is receiving the PAUSE frame momentarily stops transmitting.
–Auto (default). PAUSE frame receipt and transmission are optimized.
–Disable. PAUSE frame receipt and transmission are
disabled.
–Rx PAUSE. PAUSE frame receipt is enabled.
–Rx/Tx PAUSE. PAUSE frame receipt and transmission are enabled.
–Tx PAUSE. PAUSE frame transmission is enabled.
Jumbo Mtu. The Jumbo Mtu property allows the network adapter to transmit and receive oversized Ethernet frames that are greater than 1514 bytes, but less than 9000 bytes in length. This property requires the presence of a switch that is able to process Jumbo frames.
Frame size is set at 1500 bytes by default. To increase the size of the received frames, increment the byte quantity in
Large Send Offload. Normally the TCP segmentation is done by the protocol stack. When you enable the Large Send Offload property, the TCP segmentation can be done by the network adapter.
–Disable. Disables Large Send Offload.
–Enable. (default). Enables Large Send Offload.
Locally Administered Address. The Locally Administered Address is a
33