Allied Telesis at-8116 manual Del-vbc-domain, Set-vbc-domain Set-vbc-domain runnvramall portlist

Models: at-8116

1 88
Download 88 pages 46.82 Kb
Page 52
Image 52

Virtual LAN Commands

set-vbc-domain

set-vbc-domain {runnvramall} <port_list>

This command establishes a Virtual broadcast domain. port_list is a dash-separated list of ports to group into a broadcast domain. For example:

set-vbc-domain all 2-5-6-7

Creates a virtual broadcast domain of ports 2, 5, 6, and 7.

del-vbc-domain

del-vbc-domain {runnvram} <domain_id>

This command deletes a virtual broadcast domain. domain_id is the vbc id number as identified by get-vbc-tbl.

Note

When you use the set-vbc-domain command with the all parameter, both the runtime and nvram databases are changed. In case you need to delete the mentioned vbc entries, you should run the del-vbc- domain command twice with run and nvram parameters.

get-vbc-tbl

get-vbc-tbl {runnvram}

This command retrieves the list of defined virtual broadcast domains.

SYS_console>get-vbc-tbl run

RUNTIME VIRTUAL BROADCAST DOMAIN TABLE

===========================================

0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 VBC - 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6

1 : + + + + - - - - - - - - - - - -

2 : - - - - - - - - + + + - - - - -

SYS_console>

10-4

Page 52
Image 52