Chapter 15

Using an SNMP Manager

This chapter contains instructions for the configuration and management of the AT-8116 SNMP Management System.

Configuring the AT-8116 SNMP Agent

Global Setup

Once connected to the network and powered ON, the AT-8116 starts operating according to factory-set default values. However, to ensure proper operation and maximum performance specific to your network configuration and to provide SNMP access, some environment-specific parameters must be configured through the Command Line Interface.

If you are configuring the switch for the first time:

1.Connect a terminal to the RS-232 connector.

2.Log in to the Command Line Interface.

3.Initialize all the AT-8116 parameters to their default values (see Table 1, System Default Values). Use the following command sequence:

init-nvram (deletes all current NVRAM configrations) warm-reset (loads the NVRAM configuration)

4.Wait until you see the LOGIN prompt again. Login to the CLI. Now all system parameters have been initialized to their default values.

15-1

Page 73
Image 73
Allied Telesis at-8116 manual Using an Snmp Manager, Configuring the AT-8116 Snmp Agent