168 Operation
Chapter 5 - Command Line Interface
Default Setting
00:14:00, January 1, 1970
Command Mode
Global Configuration
Example

This example sets the system clock to 17:37 June 19, 2003.

Related Commands
sntp-server enable (page 167)
5.7.4 sntp-server daylight-saving

This command sets the start and end dates for daylight savings time. Use the no

form to disable daylight savings time.

Syntax
sntp-server daylight-saving
no sntp-server daylight-saving
Default Setting
Disabled
Command Mode
Global Configuration
Command Usage
The command sets the system clock back one hour during the specified period.
Example

This sets daylight savings time to be used from July 1st to September 1st.

5.7.5 sntp-server timezone

This command sets the time zone for the AP’s internal clock.

Enterprise AP#sntp-server date-time
Enter Year<1970-2100>: 2003
Enter Month<1-12>: 6
Enter Day<1-31>: 19
Enter Hour<0-23>: 17
Enter Min<0-59>: 37
Enterprise AP#
Enterprise AP(config)#sntp-server daylight-saving
Enter Daylight saving from which month<1-12>: 6
and which day<1-31>: 1
Enter Daylight saving end to which month<1-12>: 9
and which day<1-31>: 1
Enterprise AP(config)#