Installing Multiple Accessories continued

Priority of APC

Install SmartSlot accessories as dictated by the following

accessories:

table. An accessory with higher priority is to be placed in

Table 4

the accessory slot with the higher number.

 

Note: Share-UPS has the same priority as the SmartSlot

Interface Expander.

Accessory

P/N

Priority

Position

 

 

 

 

PowerNet

AP9605

Highest

Highest-numbered

SNMP Adapter

AP9603

 

slot.

or Web/SNMP

AP9606

 

 

Management

 

 

 

Card

 

 

 

 

 

 

 

Call-UPS®II

AP9608

Second-

Second-highest-

 

 

highest

numbered slot (high-

 

 

 

est if no PowerNet

 

 

 

SNMP or Web/

 

 

 

SNMP Management

 

 

 

Card is present.)

 

 

 

 

Relay I/O

AP9610

Third-

Any slot numbered

Module

 

highest

lower than PowerNet

 

 

 

SNMP Adapter,

 

 

 

Web/SNMP Man-

 

 

 

agement Card &

 

 

 

Call-UPSII, and

 

 

 

higher than Share-

 

 

 

UPS, Share-UPS,

 

 

 

and Measure-UPSII.

 

 

 

 

Interface

AP9607

Second

Slot higher than

Expander

AP9207

lowest

Measure-UPSII and

 

 

 

lower than all others.

 

 

 

 

Measure-UPS®

AP9612T

Lowest

In the UPS accessory

II

AP9612TH

 

slot.

 

 

 

 

 

 

 

 