NetworkAIR IR Precision Air Conditioner
Operation, Maintenance, and Troubleshooting
In-row
Page
Contents
Operation
Page
Network Management Card
Troubleshooting
Maintenance
Warranty
Display Interface
Operation
Function
Using the Display
Scrolling status screens
Main menu screen
Operation Using the Display
Navigating the interface
The Module has two levels of password protection
Stop the System
Set Up System Configuration
Up Down Horizontal
System Delays
Baud Rate. The bus speed for the RS-485bus
Applicable Settings
Options for Fluid-CooledModules
Fluid-CoilType
Actuator Types
Valve Types
Operation Options for Fluid-CooledModules
Coil Fluid Temp Activation Threshold and Deadband
Set Up Contacts and Relays
Map. Choose alarms or events to map to this relay
Page
Configure Module
Set Up Module Configuration
Alarm detectors
Set Up Module Control
Set up Humidifier
Reset variable frequency drive
Reset humidifier
Operation Set Up Module Control
Reset compressors
Control the Environment
How the modes work
Cool 61.8-90.0F16.5 to 32.2C
Cool 0.5-10.0F 0.28 -5.6C
PID controls
room load 1.Select the PID loop to tune
Humidification sensitivity
Set Up Alarms
Blower Blower Heater Humidifier
Set Up Group
Mode
Group settings
Sys failure events
Range
Page
Set Up the Display
To update the controller firmware
7.Restart the System
Set Up Network Configuration
Network config
View Status Readings
Manufacturer Name Model Number
The name of the alarm
Respond to Alarms
Reset sys failure
Clear active alarms
Operation Respond to Alarms
Displayed Alarm Message
Alarm messages and suggested actions
Action Required
Displayed Alarm Message
Action Required
Env Temperature Low
Displayed Alarm Message
Action Required
Reset Humidifier
Displayed Alarm Message
Action Required
Action Required
Displayed Alarm Message
Remote Sensor Added
Operation Respond to Alarms
Displayed Alarm Message
Action Required
Page
Quick Configuration
Network Management Card
BOOTP & DHCP configuration
TCP/IP configuration methods
APC Device IP Configuration Wizard
Network Management Card Quick Configuration
See “BOOTP” on this page or “DHCP” on page
Configuration” in the User’s Guide
2. Use the configuration cable APC part
1.Choose Network from the Control Console menu
5.Press CTRL-C to exit to the Control Console menu
Web interface
How to Access a Configured Unit
Overview
Telnet/SSH
SNMP
FTP/SCP
How to Recover From a Lost Password
How to Upgrade Firmware
5. Upgrade the AOS. For example
Page
Maintenance
Monthly Preventive Maintenance
Verify that the condensate line is flowing freely
Quarterly Preventive Maintenance
Full cooling Full reheat Humidification
Functional tests
Verify the following modes of operation
Dehumidification
Semi-AnnualPreventive Maintenance
Page
Possible Cause
Troubleshooting
Problem
Corrective Action
Corrective Action
Problem
Possible Cause
Airflow too high
Corrective Action
Problem
Possible Cause
Humidifier
Page
Warranty
Limited Product Warranty for APC Products
Drawings, descriptions
Limited Product Warranty for APC Products
Assignment of warranties
Exclusions
Page
Warranty Procedures
Warranty Procedures
Parts
Page
Page
990-2260-001
APC Worldwide Customer Support
990-2260-001
01/2005